Unauthorized IV Flushes and Inaccurate Midline Catheter Assessment
Summary
The deficiency involves the facility’s failure to ensure parenteral medications were administered according to a physician’s order and to accurately assess and document a resident’s midline catheter. A resident with intact cognition, admitted with diagnoses including UTI and ESBL infection, returned from the hospital with an IV catheter for continuation of IV Ertapenem therapy. The resident’s care plan noted IV antibiotic therapy but did not include an intervention to monitor the IV site. Facility policy required that medications be administered only upon a signed prescriber order and that PICC/midline/CVAD catheters be inspected and measured from hub to skin entry to detect migration. Surveyor review of the resident’s record showed a TAR order for weekly PICC dressing changes, which was documented as completed by the DON, but the record did not contain any order for normal saline (NS) flushes. During observation, an LPN prepared and administered Ertapenem via the resident’s catheter using a ball pump. Before starting the infusion, the LPN scrubbed the hub and flushed the catheter with 10 ml NS, then connected the antibiotic tubing and initiated the infusion. Later, after clamping the IV tubing, the LPN again scrubbed the hub and flushed the catheter with another 10 ml NS. When questioned, the LPN acknowledged there was no order for NS flushes in the medical record and stated that flushing before and after an infusion was routine practice. The DON reported having performed the resident’s catheter dressing change and stated that the external catheter length had been measured, but also stated there was no place in the record to document this measurement. The DON initially reported an external catheter length of 10 cm without the hub and 14 cm with the hub, and provided hospital placement documentation. Surveyor review of that documentation showed the device was a single-lumen power midline with an external catheter length of 0 cm. An RN from the infusion clinic confirmed the resident had a midline catheter, not a PICC, and that a midline’s external length should be 0 cm, with visible hash marks only if the catheter was migrating out. Upon being informed of this, the DON then stated there was 0 cm of external catheter visible and no hash marks seen during the dressing change, indicating the earlier measurement provided by the DON did not accurately reflect the midline catheter’s documented external length.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release August 26, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.