Medication Refrigerator Not Connected to Critical Branch Receptacle
Summary
Surveyors identified a deficiency involving the electrical supply to a medication refrigerator in the South Wing medication room. During a fire safety tour conducted with the Administrator and the Maintenance Director at 4:00 PM, it was observed that the South Wing medication room refrigerator was not plugged into a distinctly marked receptacle that was supplied from the critical branch of the essential electrical system, as required by NFPA 99. The receptacle serving this refrigerator lacked the distinctive color or marking that indicates connection to the life safety or critical branch. This issue was noted for 1 of 5 sampled medication refrigerators and was determined to affect residents residing in the South Wing, whose medications are stored in that refrigerator. The Administrator and the Maintenance Director were interviewed at the time of observation and acknowledged the findings. The deficiency and supporting photographic evidence were reviewed again with them during the exit conference at 5:30 PM. No additional resident-specific clinical details or medical histories were provided in the report.
Plan Of Correction
The statement made on this Plan of Correction are not and do not constitute an agreement with the alleged deficiencies herein. To remain in compliance with all federal and state regulations the center has taken or will take the actions set forth in the following plan of correction. The following plan of correction constitutes the centers allegation of compliance such that all alleged deficiencies cited have been or will be corrected by the date indicated. K917 Electrical Systems - Essential Electric System It is the practice of this facility to ensure the critical branch supplied power to select receptacles serving medication refrigerator. Immediate Corrective Action: The Maintenance Director was in-services regarding all refrigerators that store medicine in the medication room need to be plugged into a critical branch supplied power receptacle, identified by red cover. The Maintenance Director contacted the vendor to ensure the critical branch supplied power was properly identified. Identification of other residents potentially affected: All residents have the potential to be affected by this practice. Measures: Maintenance Director and/or designee will in-service the Maintenance Assistants regarding the facilities practice ensuring that critical branch supplied power to select receptacles serving medication refrigerator are properly identified by a red cover. Maintenance Director and/or designee will complete a House-wide audit of all the medication room to ensure that the medication refrigerator are plugged into the correct receptacle. Monitoring: Maintenance Director will random monthly audits of the refrigerators in the medication room to ensure that it is plugged into the red cover receptacle. Results of these audits will be reviewed by the QA committee during monthly meetings to ensure continued compliance. The statement made on this Plan of Correction are not and do not constitute an agreement with the alleged deficiencies herein. To remain in compliance with all federal and state regulations the center has taken or will take the actions set forth in the following plan of correction. The following plan of correction constitutes the centers allegation of compliance such that all alleged deficiencies cited have been or will be corrected by the date indicated. K917 Electrical Systems - Essential Electric System It is the practice of this facility to ensure the critical branch supplied power to select receptacles serving medication refrigerator. Immediate Corrective Action: The Maintenance Director was in-services regarding all refrigerators that store medicine in the medication room need to be plugged into a critical branch supplied power receptacle, identified by red cover. The Maintenance Director contacted the vendor to ensure the critical branch supplied power was properly identified. Identification of other residents potentially affected: All residents have the potential to be affected by this practice. Measures: Maintenance Director and/or designee will in-service the Maintenance Assistants regarding the facilities practice ensuring that critical branch supplied power to select receptacles serving medication refrigerators are properly identified by a red cover. Maintenance Director and/or designee will complete a House-wide audit of all the medication room to ensure that the medication refrigerator are plugged into the correct receptacle. Monitoring: Maintenance Director will random monthly audits of the refrigerators in the medication room to ensure that it is plugged into the red cover receptacle. Results of these audits will be reviewed by the QA committee during monthly meetings to ensure continued compliance.
Penalty
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release June 24, 2026) and official state health department websites — never guesswork.
Trusted by long-term care providers and associations.