F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
D

Failure to Ensure Timely PICC Line Dressing and IV Tubing Changes

Rochester Rehabilitation And Living CenterRochester, Minnesota Survey Completed on 04-22-2025

Summary

The facility failed to ensure proper management of peripherally inserted central catheters (PICC) for two residents receiving intravenous (IV) antibiotics. For one resident with a right knee prosthesis infection, the PICC line dressing had not been changed for ten days, as indicated by the date on the dressing and confirmed by the resident, despite the facility policy requiring dressing changes every seven days or sooner if compromised. The dressing was observed to be peeling, and the IV medication tubing lacked a date indicating when it was last changed. The resident expressed concern about the condition of both the dressing and the tubing. Documentation showed that site care was not recorded as completed until two days after the observation, and there was no physician order for dressing changes in the resident's records. A second resident with a left knee prosthesis infection also had a PICC line with an undated dressing that was peeling at multiple corners, and the IV tubing was not dated. This resident's orders specified dressing changes every seven days and as needed, but the observed condition of the dressing did not meet these requirements. Interviews with nursing staff and facility leadership confirmed that the expectation was for dressings to be changed every seven days and for IV tubing to be replaced every 24 hours, with dressings to be dated at the time of change. However, these standards were not consistently followed, as evidenced by the observations and documentation reviewed during the survey.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0694 citations
Unauthorized IV Flushes and Inaccurate Midline Catheter Assessment
D
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

A resident receiving IV Ertapenem via a midline catheter had no care plan intervention for IV site monitoring and no physician order for normal saline (NS) flushes, yet an LPN flushed the midline with NS before and after an antibiotic infusion as a routine practice. The TAR contained an order for weekly PICC dressing changes, which the DON documented as completed, but the resident actually had a midline catheter. The DON initially reported a measurable external catheter length inconsistent with the hospital placement record, which documented a midline with 0 cm external length, and only later acknowledged that no external catheter or hash marks were visible, demonstrating inaccurate assessment and documentation of the midline catheter.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Document Ordered IV Antibiotic Administration on MAR
D
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

A resident with osteomyelitis and a PICC line had physician orders for IV Vancomycin twice daily and IV Cefazolin every 8 hours, but the MAR lacked documentation for several scheduled doses. Specifically, morning Vancomycin doses and an afternoon Cefazolin dose were not recorded, despite facility guidelines requiring nurses to sign the MAR immediately after medication administration.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Measure and Document External Midline Catheter Length for IV Therapy
D
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

A resident admitted with wound infection and bacteremia received IV vancomycin via a midline catheter, but staff failed to follow facility policy and physician orders requiring measurement and documentation of the external catheter length. The care plan identified risk for complications related to the midline and called for measuring and documenting the external catheter length during dressing changes, yet the admission external length was left blank and no subsequent measurements were recorded. Observation confirmed the resident had IV access for antibiotic administration, and the DON acknowledged that the external catheter length was never documented and no insertion-length information was obtained from the hospital.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
IV Site Not Properly Labeled or Monitored During Vancomycin Infusion
D
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

A resident with multiple sclerosis, respiratory failure, sepsis, and severely impaired cognition received IV Vancomycin for pneumonia, but the IV dressing was not labeled with the insertion date, time, or staff initials. During the infusion, the RN supervisor later found the IV had infiltrated with redness and swelling. Facility policy required IV site labeling and ongoing assessment for infiltration, phlebitis, and infection.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
PICC Line Monitoring and Dressing Care Not Completed as Ordered
D
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

PICC line care was not consistently completed or documented for two residents with PICC lines for IV antibiotics. One resident with COPD and another resident with chronic osteomyelitis had orders for daily external PICC length measurements, but records showed missed documentation on multiple days. For one resident, ordered PICC dressing and cap changes every 7 days were also not documented. The Regional Administrator of Clinical Operations stated the facility did not consistently monitor and maintain the PICC lines in accordance with physician orders, facility policy, and professional standards of practice.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Timely Administer Ordered IV Hydration
D
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

A resident with cancer, malnutrition, and recent hypotension had a physician’s order for peripheral IV NS hydration over four hours on three consecutive days. The IV hydration ordered for the first day was not administered as scheduled and was instead initiated late the following day by an RN, who reported that the prior shift had not carried out the order and that no IV line was in place at the start of her shift. The DON later stated she was unaware of the missed dose and acknowledged the importance of the hydration given the resident’s hypotension. Facility IV P&P required timely initiation of infusion therapy when ordered and available from the e-kit, but this was not followed.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Minnesota

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Minnesota — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release August 26, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.