F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
D

Improper IV Therapy Administration and Infection Control Lapses

Meadow Brook Rehabilitation And NursingSalt Lake City, Utah Survey Completed on 02-22-2024

Summary

The facility failed to ensure the safe and appropriate administration of intravenous (IV) therapy for a resident, identified as Resident 26, who was observed with IV fluids improperly placed on a flat surface rather than being hung on a pole. This improper setup prevented the IV fluids from being administered correctly. Additionally, the resident's peripherally inserted central catheter (PICC) line was not covered with alcohol caps, which are essential for infection prevention. The resident expressed frustration over the lack of infection control measures, noting that nurses sometimes handled the PICC line without gloves and did not clean the port properly. Resident 26 was admitted with multiple serious health conditions, including osteomyelitis, generalized muscle weakness, polyneuropathy, type 2 diabetes mellitus with a foot ulcer, and necrotizing fasciitis. The resident required a PICC line for IV antibiotics to treat an infection in the right foot. Observations revealed that the nursing staff did not consistently follow professional standards of practice for IV therapy, as evidenced by the improper handling of the IV fluids and the lack of antiseptic barrier caps on the PICC line ports. Interviews with nursing staff, including RN 3 and RN 2, highlighted inconsistencies in infection control practices. RN 3 acknowledged the need for proper disinfection of the PICC line port and the use of a pole for IV fluid administration, while RN 2 downplayed the necessity of using antiseptic caps, citing studies that questioned their effectiveness. The Director of Nursing (DON) confirmed the oversight regarding the IV fluid placement and emphasized the nurse's responsibility to ensure proper medication administration. A referenced study underscored the importance of antiseptic barrier caps in preventing central line-associated bloodstream infections (CLABSIs).

Penalty

Inspection fine: $31,3306 days payment denial
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0694 citations
Unauthorized IV Flushes and Inaccurate Midline Catheter Assessment
D
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

A resident receiving IV Ertapenem via a midline catheter had no care plan intervention for IV site monitoring and no physician order for normal saline (NS) flushes, yet an LPN flushed the midline with NS before and after an antibiotic infusion as a routine practice. The TAR contained an order for weekly PICC dressing changes, which the DON documented as completed, but the resident actually had a midline catheter. The DON initially reported a measurable external catheter length inconsistent with the hospital placement record, which documented a midline with 0 cm external length, and only later acknowledged that no external catheter or hash marks were visible, demonstrating inaccurate assessment and documentation of the midline catheter.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Document Ordered IV Antibiotic Administration on MAR
D
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

A resident with osteomyelitis and a PICC line had physician orders for IV Vancomycin twice daily and IV Cefazolin every 8 hours, but the MAR lacked documentation for several scheduled doses. Specifically, morning Vancomycin doses and an afternoon Cefazolin dose were not recorded, despite facility guidelines requiring nurses to sign the MAR immediately after medication administration.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Measure and Document External Midline Catheter Length for IV Therapy
D
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

A resident admitted with wound infection and bacteremia received IV vancomycin via a midline catheter, but staff failed to follow facility policy and physician orders requiring measurement and documentation of the external catheter length. The care plan identified risk for complications related to the midline and called for measuring and documenting the external catheter length during dressing changes, yet the admission external length was left blank and no subsequent measurements were recorded. Observation confirmed the resident had IV access for antibiotic administration, and the DON acknowledged that the external catheter length was never documented and no insertion-length information was obtained from the hospital.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
IV Site Not Properly Labeled or Monitored During Vancomycin Infusion
D
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

A resident with multiple sclerosis, respiratory failure, sepsis, and severely impaired cognition received IV Vancomycin for pneumonia, but the IV dressing was not labeled with the insertion date, time, or staff initials. During the infusion, the RN supervisor later found the IV had infiltrated with redness and swelling. Facility policy required IV site labeling and ongoing assessment for infiltration, phlebitis, and infection.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
PICC Line Monitoring and Dressing Care Not Completed as Ordered
D
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

PICC line care was not consistently completed or documented for two residents with PICC lines for IV antibiotics. One resident with COPD and another resident with chronic osteomyelitis had orders for daily external PICC length measurements, but records showed missed documentation on multiple days. For one resident, ordered PICC dressing and cap changes every 7 days were also not documented. The Regional Administrator of Clinical Operations stated the facility did not consistently monitor and maintain the PICC lines in accordance with physician orders, facility policy, and professional standards of practice.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Timely Administer Ordered IV Hydration
D
F0694 F694: Provide for the safe, appropriate administration of IV fluids for a resident when needed.
Short Summary

A resident with cancer, malnutrition, and recent hypotension had a physician’s order for peripheral IV NS hydration over four hours on three consecutive days. The IV hydration ordered for the first day was not administered as scheduled and was instead initiated late the following day by an RN, who reported that the prior shift had not carried out the order and that no IV line was in place at the start of her shift. The DON later stated she was unaware of the missed dose and acknowledged the importance of the hydration given the resident’s hypotension. Facility IV P&P required timely initiation of infusion therapy when ordered and available from the e-kit, but this was not followed.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Utah

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Utah — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release August 26, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.