F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
D

Improper Management of Indwelling Catheter Drainage Bag and Tubing

Towers Nursing HomeSmithville, Texas Survey Completed on 04-01-2026

Summary

Surveyors identified a deficiency in the facility’s provision of catheter care for a resident with an indwelling suprapubic catheter. The resident was admitted with diagnoses including need for assistance with personal care, unspecified dementia, and a displaced intertrochanteric fracture of the left femur. The baseline care plan documented that the resident had a 16 French Foley catheter with a 10 ml balloon and specified interventions such as positioning the catheter bag and tubing below the level of the bladder and away from the room entrance, checking tubing for kinks each shift, monitoring intake and output, and monitoring for pain, discomfort, and signs and symptoms of UTI. The care plan also noted behavior problems related to hitting staff secondary to pain, but at the time the care plan was printed there was no care plan addressing the resident throwing items such as the catheter. On two separate observations the surveyor noted that the resident’s catheter drainage system was not maintained according to the care plan and facility policy. During the first observation, the resident was sitting up in bed with the bed in low position and a fall mat beside the bed; the indwelling catheter bag had kinks in the tubing and the drainage bag was lying on the floor halfway underneath the bed. A subsequent observation the same morning found the resident lying in bed with the bed still in low position, and the catheter remained kinked with the drainage bag in a covered bag lying on the floor partially under the bed. These observations showed that staff had not ensured the catheter tubing was free of kinks and that the drainage bag was not placed on the floor, contrary to the documented interventions and facility policy. Multiple staff interviews confirmed that the observed catheter positioning and tubing condition were inconsistent with expected practice and the facility’s own policy. The MDS coordinator LVN, LVNs, and CNAs interviewed all stated that catheter drainage bags should be hung on the side of the bed below the level of the bladder, that tubing should be straight and free of kinks, and that catheter bags should never be lying flat on the floor. They acknowledged that if the catheter bag was on the floor or the tubing kinked, urine might not flow properly and the resident could develop a UTI or other infection such as sepsis. The facility’s undated policy on indwelling urinary catheters explicitly directed staff to keep catheter and drainage tubing free from kinks, keep the drainage bag below the level of the bladder, and not place the drainage bag on the floor to reduce the risk of contamination and catheter-associated UTI. Despite this, the resident’s catheter bag and tubing were observed kinked and resting on the floor on more than one occasion.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0690 citations
Missing Orders and Documentation for Condom Catheter Drainage Bag Care
D
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

A resident with intact cognition and multiple diagnoses, including BPH and stroke, had a physician order for a condom catheter at bedtime, but the EMR lacked orders or instructions for cleaning, disinfecting, monitoring, or changing the drainage bag. During observation, the bag was seen hanging in the bathroom, and an LPN, RN case manager, and DON all confirmed the absence of documented guidance for the catheter drainage bag care.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Incomplete Suprapubic Catheter Orders and Care Coordination
D
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

A resident with a suprapubic catheter had incomplete orders and unclear care coordination. The care plan did not identify the SP catheter or who was responsible for catheter care and bag changes, and the MAR/TAR contained repeated orders to clarify catheter size without a documented size in the orders. Staff interviews showed uncertainty about the catheter size, who would change the catheter, and whether the listed contact number was available at all times.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Maintain Proper Indwelling Catheter Care and Bag Positioning
D
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

Surveyors found that two residents with indwelling urinary catheters did not receive care consistent with their care plans, physician orders, or facility policy. Catheter collection bags were repeatedly observed resting directly on the floor when residents were in bed or seated, and the bags were not contained in basins as specified for one resident. Required catheter care every shift was not documented, and an LPN reported that a catheter bag hung on a recliner had slipped down. The facility’s written policy required keeping catheter bags below bladder level and off the floor, as well as providing routine hygiene, but these standards were not followed.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Provide and Document Catheter Care
H
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

The facility failed to provide and document catheter care for multiple residents with Foley or suprapubic catheters. A resident with a suprapubic catheter developed drainage, vomiting, and sepsis secondary to CAUTI, while other residents had repeated catheter pain, pus, blockage, hematuria, UTIs, and hospital transfers, including ICU admission for septic shock. The record showed no catheter care orders or task documentation for several residents, and the NHA and DON confirmed the missing documentation.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Catheter Drainage Bag Allowed to Touch Floor, Breaching Infection Control
D
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

A resident receiving short-term rehab with an indwelling urinary catheter was observed in a wheelchair with the catheter drainage bag hung under the seat and touching the floor, despite facility documentation requirements that staff verify each shift that privacy bags are in place and drainage bags are not on the floor. An RN confirmed that catheter bags are not supposed to touch the floor, indicating a failure to follow established catheter care and infection control practices.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Indwelling Catheter Drainage System Left on Floor
D
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

Indwelling Catheter Drainage System Left on Floor: A resident with CKD and a UTI had an indwelling urinary catheter, but staff observed the catheter tubing and drainage bag on the floor on multiple occasions. An LPN also lifted the bag above the level of the bladder while repositioning it, and staff interviews confirmed the bag and tubing should not touch the floor.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Texas

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Texas — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release August 26, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.