F0698 F698: Provide safe, appropriate dialysis care/services for a resident who requires such services.
D

Failure to Monitor Dialysis Resident’s Fistula, Weights, and Vitals as Ordered

Careview Health And Rehab Of MinocquaMinocqua, Wisconsin Survey Completed on 04-23-2026

Summary

The deficiency involves the facility’s failure to provide dialysis care and monitoring consistent with professional standards, the resident’s care plan, and physician orders for a resident with end-stage renal disease and a left forearm fistula. The facility’s own policy on care of residents with ESRD requires staff education on ESRD management, daily/shift assessments, recognition of complications, and care of shunts and fistulas, and states that the comprehensive care plan will reflect dialysis-related needs. The resident’s care plan and physician orders specified dialysis three times weekly, monitoring of the left forearm fistula for thrill and bruit, not drawing blood or taking blood pressure in the graft arm, daily weights with pre- and post-dialysis weights on dialysis days, and vital signs on Monday, Wednesday, and Friday with notification of the provider for abnormalities. Record review showed that these ordered assessments and monitoring were not carried out or documented. The surveyor could not find documentation in the MAR, TAR, progress notes, or other records that the resident’s left forearm fistula was assessed as ordered, including monitoring for thrill and bruit or site concerns. The surveyor also could not find evidence that pre- and post-dialysis weights were obtained every Monday, Wednesday, and Friday as required; only a few scattered weight entries over several weeks were present, rather than consistent dialysis-day pre/post weights. Additionally, vital signs were not assessed and documented every Monday, Wednesday, and Friday pre and post dialysis as ordered for management of dialysis treatments and hypertension medications. The surveyor identified specific instances of abnormal blood pressure readings (186/105 mmHg and 197/96 mmHg) without documentation that the on-call provider was notified or that any interventions were implemented. Interviews with staff further demonstrated inconsistent understanding and implementation of the required dialysis-related assessments. An LPN stated that they did not do anything with the resident’s fistula, believing it to be outside their scope of practice, while an RN and the DON described expectations that staff assess the fistula, perform head-to-to-toe assessments, obtain vitals and weights, and document findings on a Dialysis Communication Form. When the surveyor requested these forms for the review period, only a limited number were produced, and the DON acknowledged that staff were not accurately monitoring the resident’s care pre and post dialysis treatments as ordered.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0698 citations
Failure to Remove Dialysis AV Fistula Dressing and Perform Ordered Assessment
D
F0698 F698: Provide safe, appropriate dialysis care/services for a resident who requires such services.
Short Summary

A resident with ESRD, peripheral vascular disease, and an AV fistula returned from dialysis with a gauze dressing applied by the dialysis nurse, which remained in place into the following day. A physician order and care plan required nursing staff to remove the AV fistula dressing on the night of dialysis and assess the site for complications and signs of infection. The assigned nurse acknowledged she knew she was required to remove the dressing and assess the site but forgot because she was busy with another resident. The physician emphasized the importance of post-dialysis AV fistula assessment due to the resident’s vascular disease and prior complications, and the DON stated she expected staff to follow the order and routinely assess the fistula site.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Follow Post-Hemodialysis AVF Dressing Orders
D
F0698 F698: Provide safe, appropriate dialysis care/services for a resident who requires such services.
Short Summary

A resident with an AVF in the right arm for hemodialysis had a physician order and care plan directing staff to keep the post-hemodialysis compression bandage on no longer than a specified number of hours and to assess and remove the dressing as ordered after each HD session. Documentation showed the resident returned from HD with the AVF dressing intact, clean, and dry and without bleeding or pain, yet the next morning the resident reported that staff had not removed the dressing, and observation confirmed the dressing was still in place. The DON and IDON verified the time-limited AVF dressing order and could not explain why the dressing had not been removed as required.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Arrange Timely Transportation Resulting in Incomplete Dialysis Treatment
D
F0698 F698: Provide safe, appropriate dialysis care/services for a resident who requires such services.
Short Summary

A resident with ESRD, COPD, severe cognitive impairment, and dependence on hemodialysis had physician orders for dialysis three times weekly with a set transportation pick-up and return time. On one treatment day, the resident was not picked up at the scheduled time, and progress notes showed the resident received only a partial dialysis session. The contracted transportation company reported that no transport had been scheduled initially and that they were called later in the morning, leading to a delayed pick-up. The SSD, who managed transportation based on standing dialysis orders, stated she did not track the contracted number of pick-up days or remaining trips, which resulted in the missed scheduled transport and shortened dialysis treatment, contrary to facility policies on transporting residents and providing appropriate hemodialysis care.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Adhere to Dialysis Resident Fluid Restriction and Medication Scheduling
D
F0698 F698: Provide safe, appropriate dialysis care/services for a resident who requires such services.
Short Summary

A resident with ESRD on dialysis, along with multiple comorbidities including CHF, COPD, A-fib, and Type 2 DM, had physician orders and a care plan for a therapeutic renal diet, a 1200 ml/day fluid restriction divided across meals and med passes, and no water pitcher in the room, consistent with facility policy for dialysis residents. Observations showed a full water pitcher at the bedside and meal trays providing more than the ordered 240 ml of fluid per meal, while documentation also reflected conflicting fluid restriction amounts. Staff confirmed the resident had been offered more fluid than ordered and that a water pitcher had been present. In addition, on a dialysis day, multiple scheduled 9 a.m. medications were not administered because the resident was away at dialysis and the facility had not coordinated medication timing around dialysis services, contrary to its own policy.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Ensure Timely Dialysis and Complete Pre/Post-Dialysis Assessments
D
F0698 F698: Provide safe, appropriate dialysis care/services for a resident who requires such services.
Short Summary

A resident with ESRD on hemodialysis, diabetes, and paraplegia was not consistently transported to dialysis on time and did not receive fully documented pre- and post-dialysis assessments as ordered. The resident reported being late to dialysis once or twice weekly, arriving after the expected chair time, and dialysis staff confirmed at least one missed transport due to the resident not being ready. Review of the MAR showed repeated omissions in required assessments of thrill, bruit, access site condition, cognition, and weight on multiple dialysis days, with no explanations in the record. Facility leadership and nursing staff described expectations for timely readiness for transport and comprehensive post-dialysis assessments, but the documentation and resident reports demonstrated that these expectations were not met.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Missed Dialysis Sessions and Incomplete Hemodialysis Assessments Due to Elevator Failures
D
F0698 F698: Provide safe, appropriate dialysis care/services for a resident who requires such services.
Short Summary

A resident with heart failure, CKD, and cirrhosis who received hemodialysis three times weekly missed one or more scheduled dialysis sessions when a malfunctioning elevator prevented timely transport, with staff and the resident confirming that elevator breakdowns had caused missed appointments and led to the resident’s relocation to a lower floor. Review of the hemodialysis communication book over several weeks showed that on most documented dialysis days, either the pre- or post-dialysis nursing assessment was missing, and there was no corresponding documentation in the EMR, despite facility policy requiring complete pre- and post-treatment assessments for dialysis care.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Know what gets cited — and walk into your next survey with full visibility

We process and analyze inspection reports and Plans of Correction using AI to surface insights and trends — so you can improve care quality and stay ahead of compliance risk before your next survey.

Get ready for your next survey

See what surveyors are citing in your state and spot your risk areas before they do.

Monthly Citation Reports

Have you been cited for this tag?

Save hours drafting a compliant Plan of Correction — AI built on real approved POCs.

Plan of Correction Writer

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release June 24, 2026) and official state health department websites — never guesswork.

Trusted by long-term care providers and associations.

Allegria Senior Living logo
FHCA logo
WeCare Centers logo
Care Rehab logo
An unhandled error has occurred. Reload 🗙