F0641 F641: Ensure each resident receives an accurate assessment.
D

Inaccurate MDS Coding for Wander Alarm and Antiplatelet Therapy

Cedarbrook Senior Care And RehabilitationAllentown, Pennsylvania Survey Completed on 04-17-2026

Summary

The facility failed to ensure an accurate MDS assessment for one sampled resident when clinical record review, observation, and staff interview showed discrepancies between physician orders and the MDS coding. The resident had vascular dementia, heart disease, and a history of stroke, with a physician’s order dated July 25, 2019 directing staff to apply a wander alert bracelet. However, the MDS assessment dated January 23, 2026 indicated in Section P (restraints and alarms) that the resident was not wearing a wander alarm during the last seven days of the look-back period, despite the order for daily use of a wander alert bracelet. Additionally, a physician’s order dated July 15, 2024 directed staff to administer aspirin as an antiplatelet medication, but the same MDS assessment documented that the resident was receiving an anticoagulant medication during the last seven days of the review period. The MDS therefore inaccurately reflected the type of medication being administered, coding aspirin as an anticoagulant instead of an antiplatelet. In an interview, the RN Assessment Coordinator confirmed that the MDS completed on January 23, 2026 was inaccurate and should have captured both the use of an antiplatelet medication and the daily use of a wander alert bracelet.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0641 citations
Inaccurate MDS Assessment Failed to Document Antidepressant Medication
D
F0641 F641: Ensure each resident receives an accurate assessment.
Short Summary

An MDS assessment failed to accurately reflect a resident's status when an antidepressant prescribed for insomnia was not documented on the admission MDS. The resident had Alzheimer's disease and major depressive disorder, and the MDS coordinator later confirmed the assessment was incorrect.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Inaccurate MDS Coding for Diabetes Medication
D
F0641 F641: Ensure each resident receives an accurate assessment.
Short Summary

A resident with diabetes had quarterly MDS assessments that incorrectly coded insulin use despite current orders showing weekly semaglutide injections and no insulin orders. The resident stated she did not receive insulin, and an RN confirmed the MDS was coded incorrectly and needed modification. The DON stated the MDS should accurately reflect each resident’s status.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Complete Required Discharge MDS Assessment
D
F0641 F641: Ensure each resident receives an accurate assessment.
Short Summary

A resident was discharged to an acute care hospital, but review of MDS listings showed that no discharge MDS assessment was completed for that resident. The MDS Coordinator acknowledged that a discharge assessment is required whenever a resident leaves the facility and could not explain why it was missed. The Executive Director reported there was no specific facility policy for MDS assessments and that staff relied on the RAI manual for guidance.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
MDS Incorrectly Omitted BiPAP Use
D
F0641 F641: Ensure each resident receives an accurate assessment.
Short Summary

A resident’s quarterly MDS failed to code use of a non-invasive ventilatory device, even though a BiPAP machine was observed at bedside and the resident stated staff assisted with it at night. The chart also included orders for CPAP/BiPAP use for OSA, and the MDS coordinator confirmed the assessment was coded incorrectly.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Inaccurate MDS Coding for Code Alert Devices
E
F0641 F641: Ensure each resident receives an accurate assessment.
Short Summary

A facility failed to accurately code MDS assessments for code alert device use for multiple residents identified as at risk for elopement and wandering. Although a wander guard log showed several residents had code alert devices, the MDS often stated the devices were not in use and did not reflect wandering behavior. Several care plans also lacked elopement or wandering interventions, and staff interviews confirmed the MDS should reflect code alert placement because it drives the care plan.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Inaccurate MDS Coding for Insulin
D
F0641 F641: Ensure each resident receives an accurate assessment.
Short Summary

Inaccurate MDS Coding for Insulin: A resident’s quarterly MDS was coded to show insulin use during the lookback period, but review of the physician’s orders and MAR found no evidence the resident received insulin. An LPN confirmed the assessment was coded inaccurately.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Pennsylvania

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Pennsylvania — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release August 26, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.