F0880 F880: Provide and implement an infection prevention and control program.
F

Failure to Maintain Water Management Controls for Stagnant Plumbing Lines

Evergreen Manor Senior Care CenterBattle Creek, Michigan Survey Completed on 04-02-2026

Summary

The facility failed to have an active and ongoing infection prevention and control program for reducing the risk of legionella and other opportunistic pathogens of premise plumbing (OPPP). During observation of the mop sink closet in the kitchen, a hot water storage tank was found where the old mop sink had been located, with the hot water line connected to the storage tank and the cold-water line connected to nothing, indicating a stagnant water line. In the 300 hall Soiled Utility room, the hopper fixture had been removed and the remaining water lines were not on a flushing schedule; the Plant Operations Director stated the facility only flushed eye wash stations and some minimal use fixtures every Friday. The POD also stated that the removed hopper lines ran through the ceiling. Additional observations showed similar conditions in other areas of the facility. In the housekeeping closet between the 300 and 400 halls, the cold-water valve had been removed from the mop sink faucet, and the POD stated the cold side was not currently flushed on Fridays. The 400 hall Soiled Utility room had a removed hopper with water lines left intact, the housekeeping closet between the 100 and 200 halls had the cold valve removed from the mop sink faucet, and the 100 hall Soiled Utility room had a removed hopper with water lines still present. In the shared bathroom at the end of the 100 hall, the commode and sink had been removed since 2020, but the water fixtures were left intact and were not on a flushing schedule. During discussion of the Water Management Plan, the POD stated the facility used monthly test strips for free chlorine, and the provided strips only showed total chlorine in 0.5 ppm increments. The facility’s Water Management Plan, dated July 1, 2025, listed a control measure requiring a free and total chlorine test kit that can accurately read to 0.1 ppm.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0880 citations
Failure to Follow Enhanced Barrier Precautions During Wound Care
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

A resident with a chronic heel wound with drainage, classified as high risk under the facility’s Enhanced Barrier Precautions (EBP) policy, received wound care from a Wound Nurse and a NA who wore masks and gloves but did not don gowns during multiple high-contact wound care activities on both lower extremities. The facility’s EBP policy requires both gloves and gowns for high-contact care, including wound care, for residents with chronic wounds. At the time of care, there was no EBP sign on the door and no PPE caddie or supplies outside the room. In subsequent interviews, the Wound Nurse and NA reported they did not wear gowns because there was no sign on the door and the nurse was not wearing one, while the IP and DON stated they would have expected gown use and confirmed that wound care is considered a high-contact activity under the policy.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Implement and Follow Enhanced Barrier Precautions During Wound Care
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Staff failed to consistently implement and follow Enhanced Barrier Precautions (EBP) during wound care for two residents. For a resident with an indwelling urinary catheter and an EBP order, an RN and a CNA removed their gowns after catheter care and performed a heel and toe dressing change wearing only gloves, despite a door sign requiring gown and gloves for wound care and other high-contact care. For another resident with multiple open leg wounds and active wound care orders, an RN and a nurse aide performed dressing changes with gloves only, without gowns, and there was no EBP signage or order in place. Interviews with nursing staff, the IP, and the DON revealed inconsistent understanding and application of the facility’s EBP policy, which requires gown and gloves for high-contact care activities, including wound care and device care, for residents with chronic wounds or indwelling devices.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Incomplete COVID Surveillance and Return-to-Work Tracking
F
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

The facility failed to fully document infection surveillance and RTW decisions during a COVID outbreak. Multiple staff members reported symptoms such as sore throat, headache, congestion, diarrhea, vomiting, fever, and cough, but the employee illness logs were incomplete and left the RTW date blank, with no indication they were tested for COVID or cleared per CDC guidance. At the same time, multiple residents were diagnosed with COVID and others had GI symptoms with unknown testing status. The IP said she worked infection control only a few hours per week and had not thoroughly reviewed the logs for trends, while the DON had not been reviewing the surveillance logs.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Cross Contamination During Dressing Change and Infection Control Program Deficiencies
E
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Cross contamination occurred during a dressing change when an LPN placed a resident’s foot directly on the wheelchair seat without a barrier and did not clean the bedside table after the procedure. The facility also lacked infection surveillance documentation for several months, and its Legionella water management plan was incomplete, with no mapping of high-risk areas, no temperature logs, and no documented preventive measures for unused areas.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Infection Control Failures During Resident Care
E
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Infection Control Failures During Resident Care: Staff did not follow PPE, hand hygiene, and equipment-cleaning practices during care for several residents. An RN failed to clean a glucometer and basket after blood sugar checks, a CNA and a Central Supply staff member entered rooms with enhanced barrier precautions without PPE, and an LVN did not clean the glucometer or insulin vial, and did not properly perform hand hygiene during insulin administration and after emptying a urinal. Residents involved had significant cognitive impairment, diabetes, wounds, and other serious diagnoses.

Inspection fine: $27,378
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Infection Control Lapses in Laundry Services and Policy Review
F
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Infection control failed during laundry services when staff reported using the same personal T-shirt for handling dirty laundry and then hanging clean laundry, while using disposable gowns only for laundry from a resident with an infection. The DON also acknowledged that the Infection Prevention Program policy was overdue for annual review, and the policy showed no indication of an annual review.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Michigan

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Michigan — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release August 26, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.