Failure to Implement Enhanced Barrier Precautions and PPE Use During High-Contact Care
Summary
The deficiency involves the facility’s failure to implement its infection prevention and control program, specifically Enhanced Barrier Precautions (EBP), for multiple residents with conditions that required heightened infection control measures. One resident was originally admitted with a left femur fracture, a left artificial hip joint, and an infection following a surgical procedure, and was later re-admitted with surgical wounds and a PICC line. Review of the resident’s records showed intact cognition and capacity to make medical decisions. On two separate observations after this re-admission, there was no EBP signage or PPE cart outside the resident’s room. In interviews, the Infection Preventionist Nurse (IPN) acknowledged that this resident should have been on EBP due to the surgical wound and that she had not yet evaluated the resident for EBP since the re-admission. The Director of Nursing (DON) also stated that the resident should have been placed on EBP upon re-admission because of the surgical wounds and PICC line, and that nurses should have initiated EBP at admission. Another deficiency occurred with a resident who had been re-admitted with diagnoses including unspecified protein caloric malnutrition, muscle weakness, and essential hypertension, and who had severely impaired cognition and required maximum assistance with toileting, transferring, and mobility. The resident had an active order for EBP related to a gastrostomy tube. Observations outside the room showed a green dot sticker by the name plate and EBP signage instructing staff to wear a gown, mask, and gloves. During an observed incontinent brief change, a CNA wore gloves and a mask but did not wear a gown. In a subsequent interview, the CNA confirmed the resident was on EBP due to the G-tube, stated that a gown should have been worn for the incontinent brief change, and acknowledged that not wearing the gown was a failure to follow infection protocol. An LVN confirmed that the green dot and signage indicated EBP and that CNAs were required to wear PPE, including gowns, during incontinent care, and described the omission of the gown as unsafe infection control practice. The IPN also confirmed that EBP was indicated for residents with devices such as feeding tubes and that the CNA should have worn a gown for the incontinent brief change. A third deficiency involved a resident admitted with Parkinson’s disease, dysphagia, and hypothyroidism, who required moderate assistance with eating and had an open sacral coccyx wound. The resident’s orders and care plan documented EBP related to the sacral coccyx open wound. Observations showed an EBP sign posted at the doorway, a green dot sticker on the name plate, and a PPE cart near the room entrance. During an observation of a meal, a CNA was seen feeding the resident while wearing only gloves, despite acknowledging that the green dot indicated some type of precaution requiring PPE during care. A registered nurse later stated that staff had to wear PPE when assisting with ADLs such as changing diapers, feeding, and showering to avoid spread of infection and contamination. Review of a local health department document and the facility’s EBP policy showed that staff were to wear gown and gloves for high-contact resident care activities, including feeding, and the DON stated that the facility’s EBP policy, which required gown and gloves for such activities, was not followed. Across these three residents, surveyors found that the facility’s own policies and procedures for its Infection Prevention and Control Program and Enhanced Standard/Barrier Precautions required prompt recognition, initiation, and implementation of EBP, and the use of PPE (gown and gloves) during high-contact care activities such as changing briefs, assisting with toileting, device care (including feeding tubes), and feeding. However, the observations and staff interviews demonstrated that EBP was not initiated for one re-admitted resident with surgical wounds and a PICC line, and that staff did not consistently use required PPE (gowns) during high-contact care for two residents already on EBP. These actions and inactions constituted the identified infection control deficiencies.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release June 24, 2026) and official state health department websites — never guesswork.
Trusted by long-term care providers and associations.