F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
E

Failure to Maintain Safe, Timely, and Sanitary Enteral Feeding Practices

The Pavilion At KentonCovington, Kentucky Survey Completed on 03-26-2026

Summary

The deficiency involves the facility’s failure to provide appropriate treatment and services to prevent complications related to enteral nutrition for six residents with feeding tubes. Surveyors found that tube feeding systems were frequently hung without being dated or timed, and tubing connector tips were left uncapped between uses, despite facility policy and manufacturer guidance requiring protection of components that contact formula. Multiple residents had feeding containers spiked and primed but not infusing, with the open ends of tubing left exposed and no protective caps available. Staff interviews confirmed that caps were not provided by the facility, and nurses acknowledged that uncovered connectors could introduce germs and place residents at risk for infection. For one resident with a gastrostomy tube and severe cognitive impairment, the care plan and orders required monitoring the G-tube site for infection every shift and checking tube placement and gastric residuals. The resident was sent twice from an adult day care center to the Emergency Department and diagnosed with abdominal wall cellulitis on both occasions, after the day care staff identified abnormal G-tube findings, including leakage and inability to flush the tube. The facility’s clinical record contained no documentation that staff had identified or recorded signs or symptoms of infection before the resident left for day care on either occasion, and the Physician Assistant reported she had not been notified of excessive leakage that could contribute to recurrent cellulitis. During observation, this resident’s G-tube site was reddened with yellowish-green drainage, the feeding container had been spiked the previous day and was being reused, the connector was left uncovered, and the pump and IV pole had dried formula residue. Other residents with PEG or G-tubes also experienced deficiencies in enteral feeding management. Several residents had tube feedings hanging and infusing without dates or times on the bags, and tubing sets were observed primed and hanging with open, uncapped ends. One resident received medications via PEG tube without the nurse checking tube placement beforehand, despite a care plan intervention to check placement and gastric contents per protocol. Another resident’s feeding was labeled to start later in the day but was already spiked and primed hours in advance, with the connector left uncovered and the pump and IV pole soiled with dried feeding residue. For a resident ordered to receive tube feeding from late afternoon to early morning, the feeding was started approximately two hours late and then observed still infusing well past the ordered stop time; the resident was later found in bed with a large amount of emesis on the gown and linens, and the LPN stated she had been running behind and had not turned off the feeding. Throughout these observations, the DON, PA, RD, and product representative all confirmed that connectors should be covered, feedings should follow ordered schedules, and systems should not remain hanging beyond recommended timeframes, but the facility’s practices did not align with these expectations. Across multiple days of observation, the surveyors repeatedly noted that enteral feeding pumps and IV poles for several residents were coated with dried feeding residue on the exterior surfaces, along the poles, and at the bases, indicating that equipment used for tube feeding was not maintained in a clean and sanitary condition. Facility policies on enteral nutrition and G-tube site care required staff to monitor for signs of infection, maintain cleanliness of the tube site, assess for redness, swelling, pain, or drainage, and report signs of infection to a supervisor and physician. The policies also emphasized confirming tube placement prior to initiating feedings to reduce aspiration risk and recognizing complications such as aspiration, tube misplacement, skin breakdown, and gastrointestinal symptoms. Despite these written policies and the manufacturer’s guidance on closed versus open systems, hang times, labeling, and handling to prevent contamination, staff actions and inactions—including failure to document and report abnormal G-tube findings, failure to verify tube placement before medication administration, failure to adhere to ordered feeding schedules, and failure to keep connectors capped and equipment clean—led to the cited deficiency for all six residents receiving enteral nutrition.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0693 citations
Incorrect G-tube Flush Volume During Enteral Feeding
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

Incorrect G-tube Flush Volume During Enteral Feeding: A resident with severe cognitive impairment, aphasia, stroke, hemiplegia, and a feeding tube was observed receiving enteral feeding when an RN flushed the G-tube with 30 ml of water before and after the feeding instead of the ordered 60 ml. The RN stated he read the order wrong, and the DON and ADON confirmed the correct flush amount should have been followed.

Fine: $9,821
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Provide Ordered Hydration and Correct Tube Flushes for Enteral Feeding
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with moderate cognitive impairment, multiple comorbidities, and NPO status received nutrition and hydration via a gastrojejunal tube with orders for continuous tube feeding, 30 mL water flushes before and after medications via the gastric port, 120 mL free water flushes six times daily, and 30 mL jejunal port flushes every four hours. During observed care, an LPN administered medications and 30 mL water flushes through the gastric port but did not provide the ordered 120 mL free water flush or the 30 mL jejunal port flush, and no additional flushes were given over several hours. Later, another LPN initially attempted to give medications through the jejunal port before being redirected, and documentation on the MAR/TAR showed inconsistent flush volumes of 30–60 mL instead of the ordered 120 mL free water flushes, reflecting failure to consistently implement the prescribed hydration and port-specific flushing regimen.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Improper Head-of-Bed Positioning During Tube Feeding
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident receiving enteral tube feeding was observed lying with the HOB elevated only 15 degrees while Glucerna was infusing at 60 ml/hr. An LVN started the feeding and was unsure of the correct HOB position, and an RN stated the HOB was not elevated properly to prevent aspiration. Records showed an order to keep the HOB elevated 30-45 degrees or as tolerated and a care plan noting tube feeding related to dysphagia.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
GT Site Care and Feeding Position Not Provided as Ordered
E
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

GT site care and feeding precautions were not followed for two residents with GTs. One resident with dementia and severe cognitive impairment had a GT dressing left unchanged despite orders for daily cleansing and dressing changes, and drainage was observed at the site. Another resident was observed lying flat in a supine position while receiving continuous GT feeding, even though the CP and OSR required HOB elevation during tube feeding; RN and DON confirmed the ordered positioning was not being followed.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Expired Tube Feeding Formula Left Connected to Resident
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

Expired Tube Feeding Formula Left Connected to a Resident: A resident with anoxic brain damage, dysphagia, and a gastrostomy tube was observed with an enteral feeding pump off but still connected and a tube feeding bag that staff said had exceeded the 24-hour limit after opening. Staff confirmed the formula was no longer safe after 24 hours, and the facility policy required accurate labeling and dating of each feeding bag or formula container.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
GT Not Flushed Before Medication Administration
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

GT Not Flushed Before Med Pass: An LPN was observed preparing to give crushed meds through a resident’s GT without first flushing the tube with water. The surveyor stopped the med pass before any meds were given, and both the LPN and DON confirmed the GT had not been flushed as required by the resident’s order and facility policy.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Know what gets cited — and walk into your next survey with full visibility

We process and analyze inspection reports and Plans of Correction using AI to surface insights and trends — so you can improve care quality and stay ahead of compliance risk before your next survey.

Get ready for your next survey

See what surveyors are citing in your state and spot your risk areas before they do.

Monthly Citation Reports

Have you been cited for this tag?

Save hours drafting a compliant Plan of Correction — AI built on real approved POCs.

Plan of Correction Writer

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release June 24, 2026) and official state health department websites — never guesswork.

Trusted by long-term care providers and associations.

Allegria Senior Living logo
FHCA logo
WeCare Centers logo
Care Rehab logo
An unhandled error has occurred. Reload 🗙