F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
D

Failure to Assess and Report Abnormal Urine and Catheter Findings

Plymouth PlaceLa Grange Park, Illinois Survey Completed on 02-26-2026

Summary

The facility failed to assess, monitor, and provide timely medical interventions for a resident with an indwelling urinary catheter who exhibited signs consistent with possible urinary tract infection (UTI). The resident had multiple diagnoses, including neuromuscular dysfunction of the bladder and neurogenic bladder, and had an order for catheter care every shift. The care plan identified the resident as being at risk for infection related to the indwelling catheter and required staff to empty drainage bags regularly and monitor, record, and report signs and symptoms of UTI, such as cloudy urine and sediment. On two consecutive days, surveyors observed the resident’s catheter bag and tubing containing dark, cloudy yellow urine with large, thick white clumps of sediment. Despite these visible abnormalities, there were no corresponding progress note entries documenting the condition of the catheter, any assessment of the urine, or notification to the physician from the beginning of the month through the time of the survey. Staff interviews further demonstrated a lack of appropriate response to the resident’s catheter condition. A CNA reported being trained to look for blood, cloudiness, thickness, and darkness in catheter tubing or bags and to alert the nurse if such findings were present, but stated there were no observations or concerns regarding this resident’s catheter and no unusual occurrences reported from the previous shift. An agency LPN stated that signs of infection include sediment or blood in the tubing and cloudy urine, and that such findings should prompt a call to the physician for orders and urine testing, but reported being unaware of any concerns with the resident’s catheter and not receiving any report of sediment or cloudy urine. The DON stated that staff should observe for discoloration and other signs of potential infection and obtain physician orders when such signs are noted, and confirmed she had not been made aware of the resident’s catheter condition. Review of the facility’s urinary catheter care policy showed that staff are required to observe urine for unusual appearance, report findings to the physician and supervisor immediately, and document assessment data and urine characteristics, which was not done in this case.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0690 citations
Missing Orders and Documentation for Condom Catheter Drainage Bag Care
D
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

A resident with intact cognition and multiple diagnoses, including BPH and stroke, had a physician order for a condom catheter at bedtime, but the EMR lacked orders or instructions for cleaning, disinfecting, monitoring, or changing the drainage bag. During observation, the bag was seen hanging in the bathroom, and an LPN, RN case manager, and DON all confirmed the absence of documented guidance for the catheter drainage bag care.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Incomplete Suprapubic Catheter Orders and Care Coordination
D
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

A resident with a suprapubic catheter had incomplete orders and unclear care coordination. The care plan did not identify the SP catheter or who was responsible for catheter care and bag changes, and the MAR/TAR contained repeated orders to clarify catheter size without a documented size in the orders. Staff interviews showed uncertainty about the catheter size, who would change the catheter, and whether the listed contact number was available at all times.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Maintain Proper Indwelling Catheter Care and Bag Positioning
D
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

Surveyors found that two residents with indwelling urinary catheters did not receive care consistent with their care plans, physician orders, or facility policy. Catheter collection bags were repeatedly observed resting directly on the floor when residents were in bed or seated, and the bags were not contained in basins as specified for one resident. Required catheter care every shift was not documented, and an LPN reported that a catheter bag hung on a recliner had slipped down. The facility’s written policy required keeping catheter bags below bladder level and off the floor, as well as providing routine hygiene, but these standards were not followed.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Provide and Document Catheter Care
H
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

The facility failed to provide and document catheter care for multiple residents with Foley or suprapubic catheters. A resident with a suprapubic catheter developed drainage, vomiting, and sepsis secondary to CAUTI, while other residents had repeated catheter pain, pus, blockage, hematuria, UTIs, and hospital transfers, including ICU admission for septic shock. The record showed no catheter care orders or task documentation for several residents, and the NHA and DON confirmed the missing documentation.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Catheter Drainage Bag Allowed to Touch Floor, Breaching Infection Control
D
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

A resident receiving short-term rehab with an indwelling urinary catheter was observed in a wheelchair with the catheter drainage bag hung under the seat and touching the floor, despite facility documentation requirements that staff verify each shift that privacy bags are in place and drainage bags are not on the floor. An RN confirmed that catheter bags are not supposed to touch the floor, indicating a failure to follow established catheter care and infection control practices.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Indwelling Catheter Drainage System Left on Floor
D
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

Indwelling Catheter Drainage System Left on Floor: A resident with CKD and a UTI had an indwelling urinary catheter, but staff observed the catheter tubing and drainage bag on the floor on multiple occasions. An LPN also lifted the bag above the level of the bladder while repositioning it, and staff interviews confirmed the bag and tubing should not touch the floor.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Illinois

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Illinois — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release August 26, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.