F0695 F695: Provide safe and appropriate respiratory care for a resident when needed.
D

Failure to Follow Respiratory and Tracheostomy Care Orders and Sterile Technique

Belpre Landing Nursing And RehabilitationBelpre, Ohio Survey Completed on 01-30-2026

Summary

The deficiency involves the facility’s failure to provide respiratory care as ordered for two residents who required complex airway management. One resident was admitted with sepsis, pneumonia, and acute and chronic respiratory failure with hypoxia, and had care plans addressing alterations in respiratory function, dependence on a tracheostomy and ventilator, and the need for oxygen therapy and respiratory treatments. The resident had a physician order dated 01/12/26 for the heat moisture exchange (HME) device to be changed daily and as needed. Review of the treatment administration record (TAR) for January 2026 showed the HME was documented as changed only on 01/12/26, 01/15/26, and 01/21/26, with no additional evidence that the HME was changed daily as ordered. Further review of respiratory progress notes documented that respiratory therapists performed trach care, oral care, suctioning, inner cannula changes, and HME changes on specific dates, but these entries did not establish that the HME was changed every day as required by the order. The nurse practitioner confirmed that the TAR reflected only as-needed HME replacement and that she was not familiar with HMEs until she researched them and learned they humidify air so the lungs do not get dry. She also stated she did not give orders for tracheostomy or ventilator care and was unsure where those orders originated. The DON acknowledged that the HME order stated it should be changed daily but had been entered into the system as an as-needed order, and reported being told by an RT that HME changes were considered part of standard ventilator care and therefore did not require a separate order. An RT later explained that HMEs are used for humidification, are good for 24 hours, and are changed every time care is completed, and stated that the HME must have its own separate order because ventilator care documentation alone does not confirm that the HME was changed. This RT described the HME order entry as a clerical error and expressed confidence that daily care was being completed based on his checks of HME dates, but there was no documentation to support daily changes as ordered. The nurse practitioner also identified concerns related to not changing the HME, including pneumonia related to bacteria or aspiration due to increased airway resistance, mucus plugging, hypothermia, pneumonia, and potential respiratory distress. The second resident was admitted with multiple sclerosis, chronic respiratory failure with hypoxia, a tracheostomy, ventilator dependence, and a history of ventilator-associated pneumonia and sepsis. The care plan for alteration in respiratory function and tracheostomy/ventilator use included interventions to change the size 6 disposable tracheostomy inner cannula and cleanse the tracheostomy site as ordered. Physician orders directed staff to cleanse the tracheostomy site with sterile water, pat dry, apply a drain sponge, and change every shift and as needed, and to change the size 6 Shiley tracheostomy inner cannula every shift and as needed. During an observed tracheostomy inner cannula and site care procedure for this resident, the RT donned a gown, performed hand hygiene, and used non-sterile gloves but did not wear a mask. Treatment supplies were placed on a bedside table that also contained personal items, and no barrier or sterile field was used. The RT discarded the sterile gloves from the tracheostomy kit because they were the wrong size, then handled sterile items from the kit with non-sterile gloves, prepared cleaning solutions, and cleansed the tracheostomy stoma using split gauze held with non-sterile gloves. After changing gloves and performing hand hygiene, the RT placed a split gauze around the stoma and then, again using non-sterile gloves, removed the used inner cannula and inserted a new sterile disposable inner cannula before reconnecting the ventilator tubing. The DON verified that tracheostomy care was supposed to be completed using sterile technique, including sterile gloves, a barrier for supplies, and appropriate personal protective equipment such as a mask. The RT confirmed he did not use a barrier or mask and used non-sterile gloves because the sterile gloves in the kit did not fit, despite acknowledging that sterile gloves were available in the facility. He stated that he performed the procedure using a non-sterile technique and asserted that the facility policy, which required sterile technique at all times for tracheostomy and trach tube care, was wrong. The written policy specified that meticulous tracheostomy care was mandatory to prevent complications, that the tracheostomy stoma should be cleansed regularly using sterile technique at all times, and that the inner cannula should be cleaned regularly using sterile technique at all times, underscoring that the observed practice did not follow the established standard. This deficiency represents an incidental finding of non-compliance investigated under Complaint Number 2702282.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0695 citations
Unsecured Storage of Full Oxygen Cylinders on Nursing Unit
D
F0695 F695: Provide safe and appropriate respiratory care for a resident when needed.
Short Summary

Surveyors observed four full O2 cylinders on one nursing unit stored unsecured directly on the floor under a sign labeled "FULL CYLINDERS" instead of in a secured storage rack. The ADON confirmed the cylinders were full and should not be on the ground. Reference to NFPA 99 showed that freestanding cylinders must be protected from damage and properly chained or supported in a stand or cart. The DON and Maintenance Director both acknowledged that O2 cylinders are required to be stored in a secure rack, should never be on the floor, and that unsecured cylinders on the floor present a safety risk.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Improper Handling and Storage of Oxygen Nasal Cannula
D
F0695 F695: Provide safe and appropriate respiratory care for a resident when needed.
Short Summary

A resident with severe cognitive impairment and COPD, receiving oxygen therapy via nasal cannula, was observed twice with the cannula lying on the floor beside the bed instead of stored in the bag on the oxygen concentrator as required. A CNA later picked up the cannula from the floor, wiped it with a non-disinfectant incontinent wipe, and reapplied it to the resident, despite having been trained that a cannula found on the floor should be replaced. An LVN, the DON, and the Administrator all confirmed that oxygen cannulas must be stored properly, replaced if found on the floor, and that incontinent wipes are not disinfectants, indicating a failure to follow the facility’s infection prevention and control policy.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Improper Storage of Nebulizer Mask and Respiratory Supplies
D
F0695 F695: Provide safe and appropriate respiratory care for a resident when needed.
Short Summary

A resident with COPD and dementia, receiving scheduled nebulizer treatments, was found on multiple occasions to have a nebulizer mask stored on top of the machine rather than in a sanitary manner. A CNA and a nurse aide in training confirmed the mask’s placement, and an LPN reported that masks were routinely cleaned, dried, and then stored on top of the machine. The DON later acknowledged that masks should be washed, dried, and placed on a clean surface, and facility policy required oxygen and respiratory supplies to be stored in a plastic bag when not in use.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Oxygen Administered Without Required Physician Order
D
F0695 F695: Provide safe and appropriate respiratory care for a resident when needed.
Short Summary

A resident with acute respiratory failure with hypoxia, pulmonary hypertension, and type 2 diabetes was observed receiving oxygen at 4.5 L/min via nasal cannula without a corresponding physician order in the clinical record. The DON acknowledged that an order should have been in place before oxygen was initiated. Facility policy on supplemental oxygen via nasal cannula requires administration only under a physician or provider order, in alignment with 410 IAC 16.2-3.1-47(a)(6).

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Missing Current Physician Order for Oxygen
D
F0695 F695: Provide safe and appropriate respiratory care for a resident when needed.
Short Summary

A resident was observed receiving O2 via nasal cannula on multiple occasions, but the chart had no current physician order for O2. The resident said she had been told after a recent hospitalization to use O2 for 30 days, but that time had passed and she was still using it because staff told her she needed it. The DON confirmed there was no current O2 order; the last order had already been discontinued.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Provide and Document Respiratory Care
E
F0695 F695: Provide safe and appropriate respiratory care for a resident when needed.
Short Summary

Failure to provide and document respiratory care: A resident with a trach had no documented evidence of respiratory rate, depth, and quality being monitored each shift and as needed, despite oxygen orders and trach care needs. Other residents with CPAP, nebulizer, and oxygen therapy had respiratory equipment left out of required storage, missing CPAP settings and care details in orders and care plans, and MAR entries signed by nursing staff even when respiratory staff reportedly completed the equipment changes.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Ohio

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Ohio — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release August 26, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.