F0759 F759: Ensure medication error rates are not 5 percent or greater.
D

Medication Administration Errors with Insulin and Pantoprazole

Dublin Post AcuteDublin, Ohio Survey Completed on 01-26-2026

Summary

The deficiency involves a failure to maintain a medication error rate below 5%, with surveyors identifying 3 errors out of 25 observed medication administration opportunities, resulting in a 12% error rate. One resident with chronic kidney disease and aftercare for joint replacement had a physician order for pantoprazole 40 mg packet to be dissolved in 5 milliliters of apple juice and given once daily. During observation, a Certified Medication Aide (CMA) poured the pantoprazole packet into a cup of water and administered it, rather than using apple juice as ordered and as required by FDA instructions for pantoprazole delayed-release oral suspension. The Executive Director confirmed that the electronic MAR did not specify administration in apple juice or applesauce, and FDA guidance indicated pantoprazole granules must be given only in apple juice or applesauce due to pH requirements and specific preparation instructions. Another resident, admitted and readmitted with diagnoses including metabolic encephalopathy and type 2 diabetes, had a care plan addressing potential for unmanaged blood sugar and an order for Lantus insulin 18 units twice daily. During observation, an RN drew up Lantus in an insulin syringe, and when asked to verify the dose, the syringe’s black stopper was at the 20-unit mark. The RN initially asserted that the surveyor was looking at the wrong side of the syringe and claimed that one side showed 1-unit increments and the other 2-unit increments, stating she had drawn up 18 units. Upon further questioning, the RN rechecked the syringe and adjusted the plunger to the 18-unit mark. The DON later verified that the insulin syringe was marked in 1-unit increments on both sides, confirming that the RN had initially prepared an incorrect dose. A third resident with a fracture of the left femur and type 2 diabetes had a care plan for altered endocrine function and an order for Humalog insulin 19 units before every meal. During observation, the CMA removed a new Humalog KwikPen from the medication cart, dialed it directly to 19 units, and prepared to administer it. When the surveyor asked whether the pen needed to be primed, the CMA stated she did not understand the question and again indicated she did not know what priming was before entering the resident’s room to administer the insulin. Manufacturer instructions for the Humalog KwikPen specified that the pen must be primed before each injection by selecting 2 units, holding the pen needle-up, tapping to collect air bubbles, and pushing the dose knob until zero appears, to ensure proper function and accurate dosing. These events occurred despite facility policies and the medication aide job description requiring staff to follow medication labels, verify orders, and administer medications in accordance with established nursing standards, facility policies, and state requirements.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0759 citations
Insulin Administration Errors and Failure to Prime Insulin Pens
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Surveyors identified that the facility exceeded the acceptable medication error rate when two residents with type 2 DM received insulin doses that were not administered according to orders or manufacturer instructions. In two separate observations, an LPN administered Novolog and another LPN administered insulin glargine and insulin lispro without priming the insulin pens, and the insulin lispro and Novolog were given after the residents had already consumed a significant portion of their breakfast meals, despite orders for administration before meals. Manufacturer information for both insulin products required priming before each injection to ensure accurate dosing, and facility policy required medications, including insulin, to be administered safely, timely, and in accordance with prescriber orders and specified time frames.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Ensure Accurate Medication Dosage Identification During Medication Pass
E
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

The facility failed to maintain medication error rates below 5% when an LPN, during a medication pass for a resident receiving Metamucil for constipation and a cranberry supplement for UTI prevention, was unable to identify the correct dosages for these ordered medications. Despite a policy requiring adherence to the rights of medication administration, including the right dose, the LPN reported that the orders should have been clarified to specify the exact dose, indicating medications were being prepared and administered without clear dosage understanding and contributing to an overall medication error rate above the acceptable threshold.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Maintain Acceptable Medication Error Rate and Proper Medication Timing
E
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Surveyors found that the facility did not maintain a medication error rate below 5%, identifying multiple late and improperly timed medication administrations and a missing medication. A medication aide gave a cholesterol medication and wound-healing supplements significantly later than their scheduled times, and another aide administered acetaminophen well outside the ordered time window and could not obtain a prescribed dose of Ingrezza because it had not arrived from the pharmacy. An LPN administered fast-acting Humalog insulin before a meal when no food was available and was unaware of the required timing of insulin in relation to meals, while the facility’s insulin policy lacked guidance on meal-related timing despite manufacturer instructions specifying administration within 15 minutes before or immediately after eating.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Administration Errors and Unavailable Ordered Medications
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Surveyors identified an 11.1% medication error rate when an LPN did not administer a resident’s ordered nifedipine ER dose because it was not available in the cart or pyxis, and proceeded with the rest of the medications. In a separate instance, an RN administered furosemide despite the order having been discontinued and gave magnesium oxide instead of the ordered SlowMag, explaining that he relied on scanning multi-drug packets rather than individually verifying each medication against the MAR, and knowingly substituted magnesium oxide when SlowMag was unavailable.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Error Rate Above 5% Due to Incorrect Dosing and Insulin Pen Technique
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Surveyors identified a medication error rate of 7.41%, exceeding the 5% threshold, involving two residents and two LPNs. In one case, a resident with dementia and hypertension received 5 mg of donepezil instead of the 10 mg dose ordered. In another case, a resident with DM2 received insulin lispro via a KwikPen that was not primed, and the LPN held the dose knob for only about 2 seconds instead of the manufacturer-recommended 5 seconds. The DON reported that staff had not been educated on proper insulin pen priming, and facility policy requires verification of the correct medication and dose before administration.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Error Rate Exceeded Due to Unavailable Ordered Medications
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

The facility failed to keep its medication error rate below 5% when a resident with dementia, COPD, diabetes, and depression did not receive ordered doses of Singulair and calcium/vitamin D3 because the medications were not available at the time of administration. An RN attempted to pass the morning medications but was unable to administer these two ordered drugs, and later confirmed their unavailability, resulting in two errors out of 33 medication opportunities and an overall error rate of 6.06%.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Know what gets cited — and walk into your next survey with full visibility

We process and analyze inspection reports and Plans of Correction using AI to surface insights and trends — so you can improve care quality and stay ahead of compliance risk before your next survey.

Get ready for your next survey

See what surveyors are citing in your state and spot your risk areas before they do.

Monthly Citation Reports

Have you been cited for this tag?

Save hours drafting a compliant Plan of Correction — AI built on real approved POCs.

Plan of Correction Writer

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release June 24, 2026) and official state health department websites — never guesswork.

Trusted by long-term care providers and associations.

Allegria Senior Living logo
FHCA logo
WeCare Centers logo
Care Rehab logo
An unhandled error has occurred. Reload 🗙