F0880 F880: Provide and implement an infection prevention and control program.
E

Failure to Follow COVID-19 PPE, Isolation, Testing, and Test-Expiration Requirements During Outbreak

The Greens At LincolntonLincolnton, North Carolina Survey Completed on 02-12-2026

Summary

The deficiency involves the facility’s failure to follow its own infection prevention and control policies and current CDC guidance during an ongoing COVID-19 outbreak. The facility policy required staff entering rooms of residents with suspected or confirmed COVID-19 to use an N95 or higher-level respirator, gown, gloves, and eye protection. One resident who tested positive for COVID-19 was placed on transmission-based precautions (TBP) with a door sign specifying gown, gloves, N95, and eye protection. A nurse aide entered this resident’s room wearing a gown, gloves, and mask but without eye protection, and there was no eye protection available on the PPE caddy outside the room. The nurse aide stated she believed her eyeglasses counted as eye protection. The infection prevention (IP) nurse, ADON, Administrator, and Regional Nurse all confirmed that full PPE, including eye protection, was required and that staff had been educated, but they could not explain why the nurse aide did not comply. The facility also failed to ensure appropriate PPE use during COVID-19 specimen collection. CDC interim guidelines for collecting and handling clinical specimens for COVID-19 require an N95 or higher-level respirator, eye protection, gloves, and gown for healthcare providers collecting specimens or working within 6 feet of patients suspected to be infected. The facility did not have a policy addressing PPE for COVID-19 specimen collection. During observation of resident COVID testing, one unit manager collecting nasal swabs wore an N95, gown, and gloves but did not wear eye protection, while another unit manager handling the specimens in the hallway wore an N95 and gloves. The IP nurse and ADON stated that full PPE, including eye protection, should be worn for COVID testing and that the facility had an adequate supply of face shields. The unit manager who collected the specimen reported she was unsure if eye protection was required and only obtained face shields after consulting someone from corporate. The facility failed to follow CDC return-to-work criteria for staff with COVID-19 and did not maintain adequate records of staff testing. The facility’s policy referenced CDC interim guidance for managing healthcare personnel with COVID-19 infection, which requires at least 7 days since symptom onset with a negative viral test within 48 hours prior to return (or 10 days if testing is not performed or if the day 5–7 test is positive), and, if using antigen tests, negative tests on day 5 and again 48 hours later. Review of the facility’s COVID-positive staff log showed 12 staff had tested positive, and 9 returned to work before 10 days from symptom onset without documentation of negative tests on both day 5 and day 7. The IP nurse stated staff were tested with antigen tests on day 5 and allowed to return to work on day 7 if that test was negative, and that she did not perform or document a second test on day 7. She also stated staff performed self-testing, that tests were placed in the break room or taken home, and that there was no process to track when staff tested, whether they tested as required, or whether tests were performed according to manufacturer instructions. The facility Physician and Administrator stated the facility should follow its infection control policies and CDC guidance, and the Administrator acknowledged there was no oversight or logging of staff COVID test results. The facility also failed to maintain TBP for COVID-positive residents in accordance with its policy and CDC guidance. The facility’s policy required residents with mild to moderate illness who were not moderately to severely immunocompromised to remain on TBP for at least 10 days after symptom onset, with additional criteria for severe illness and for test-based strategies requiring two negative tests 48 hours apart. Review of the COVID-positive resident log showed that multiple residents were removed from TBP after 7–9 days from symptom onset, rather than after the full 10 days. The IP nurse stated residents were tested with antigen tests on day 5 and, if negative, were removed from TBP after 7 days; if positive on day 5, TBP continued for 10 days. She reported she did not perform a second test on day 7 before discontinuing TBP and was unaware that two negative tests 48 hours apart were required when using a testing strategy. She also stated that TBP orders were entered for 10 days in the electronic system but were not discontinued when residents were taken off precautions earlier. Additionally, the facility used expired COVID-19 test kits for resident and staff testing during the outbreak and did not follow manufacturer expiration dates. Observations in the staff break room showed boxes of two different brands of COVID tests with expiration dates already passed. The IP nurse stated three brands of COVID tests, all with listed expiration dates that had passed, were used for staff and resident testing during the outbreak and that she believed the tests could be used for six months beyond the printed expiration date. Customer service representatives for each test manufacturer confirmed that the lot numbers in question did not have extended expiration dates, that the printed expiration dates were final, and that tests used after those dates would not be considered accurate or valid, with potential for false negative or false positive results. The Health Department nurse stated the facility had recently contacted them about using expired tests and that the department was working on guidance. The facility Physician stated that using expired COVID tests could affect test efficacy, that the protein in the test solution breaks down over time, and that expired tests could produce false negative results.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0880 citations
Failure to Implement and Follow Enhanced Barrier Precautions During Wound Care
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Staff failed to consistently implement and follow Enhanced Barrier Precautions (EBP) during wound care for two residents. For a resident with an indwelling urinary catheter and an EBP order, an RN and a CNA removed their gowns after catheter care and performed a heel and toe dressing change wearing only gloves, despite a door sign requiring gown and gloves for wound care and other high-contact care. For another resident with multiple open leg wounds and active wound care orders, an RN and a nurse aide performed dressing changes with gloves only, without gowns, and there was no EBP signage or order in place. Interviews with nursing staff, the IP, and the DON revealed inconsistent understanding and application of the facility’s EBP policy, which requires gown and gloves for high-contact care activities, including wound care and device care, for residents with chronic wounds or indwelling devices.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Follow Enhanced Barrier Precautions During Wound Care
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

A resident with a chronic heel wound with drainage, classified as high risk under the facility’s Enhanced Barrier Precautions (EBP) policy, received wound care from a Wound Nurse and a NA who wore masks and gloves but did not don gowns during multiple high-contact wound care activities on both lower extremities. The facility’s EBP policy requires both gloves and gowns for high-contact care, including wound care, for residents with chronic wounds. At the time of care, there was no EBP sign on the door and no PPE caddie or supplies outside the room. In subsequent interviews, the Wound Nurse and NA reported they did not wear gowns because there was no sign on the door and the nurse was not wearing one, while the IP and DON stated they would have expected gown use and confirmed that wound care is considered a high-contact activity under the policy.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Incomplete COVID Surveillance and Return-to-Work Tracking
F
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

The facility failed to fully document infection surveillance and RTW decisions during a COVID outbreak. Multiple staff members reported symptoms such as sore throat, headache, congestion, diarrhea, vomiting, fever, and cough, but the employee illness logs were incomplete and left the RTW date blank, with no indication they were tested for COVID or cleared per CDC guidance. At the same time, multiple residents were diagnosed with COVID and others had GI symptoms with unknown testing status. The IP said she worked infection control only a few hours per week and had not thoroughly reviewed the logs for trends, while the DON had not been reviewing the surveillance logs.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Cross Contamination During Dressing Change and Infection Control Program Deficiencies
E
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Cross contamination occurred during a dressing change when an LPN placed a resident’s foot directly on the wheelchair seat without a barrier and did not clean the bedside table after the procedure. The facility also lacked infection surveillance documentation for several months, and its Legionella water management plan was incomplete, with no mapping of high-risk areas, no temperature logs, and no documented preventive measures for unused areas.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Infection Control Failures During Resident Care
E
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Infection Control Failures During Resident Care: Staff did not follow PPE, hand hygiene, and equipment-cleaning practices during care for several residents. An RN failed to clean a glucometer and basket after blood sugar checks, a CNA and a Central Supply staff member entered rooms with enhanced barrier precautions without PPE, and an LVN did not clean the glucometer or insulin vial, and did not properly perform hand hygiene during insulin administration and after emptying a urinal. Residents involved had significant cognitive impairment, diabetes, wounds, and other serious diagnoses.

Fine: $27,378
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Infection Control Lapses in Laundry Services and Policy Review
F
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Infection control failed during laundry services when staff reported using the same personal T-shirt for handling dirty laundry and then hanging clean laundry, while using disposable gowns only for laundry from a resident with an infection. The DON also acknowledged that the Infection Prevention Program policy was overdue for annual review, and the policy showed no indication of an annual review.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Know what gets cited — and walk into your next survey with full visibility

We process and analyze inspection reports and Plans of Correction using AI to surface insights and trends — so you can improve care quality and stay ahead of compliance risk before your next survey.

Get ready for your next survey

See what surveyors are citing in your state and spot your risk areas before they do.

Monthly Citation Reports

Have you been cited for this tag?

Save hours drafting a compliant Plan of Correction — AI built on real approved POCs.

Plan of Correction Writer

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release June 24, 2026) and official state health department websites — never guesswork.

Trusted by long-term care providers and associations.

Allegria Senior Living logo
FHCA logo
WeCare Centers logo
Care Rehab logo
An unhandled error has occurred. Reload 🗙