F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
D

Inaccurate Measurement of Physician-Ordered Tube Feeding Volume

Resthave Home-whiteside CountyMorrison, Illinois Survey Completed on 01-29-2026

Summary

The facility failed to ensure accurate measurement and administration of physician-ordered tube feeding for a resident receiving bolus enteral nutrition. The resident had a feeding tube, was NPO, and had an order for Jevity 1.5 cal with fiber, 240 ml via feeding tube five times daily, totaling 1,200 ml per day, for nutrition support related to esophageal dysphagia that had led to malnutrition. During observation of a scheduled tube feeding, an RN used a 30 ml medicine cup and a 120 ml drinking cup to measure the formula instead of the syringe provided for accurate measurement. The RN repeatedly filled the 30 ml cup without verifying the volume at the marked 30 ml line and poured these unmeasured amounts into the drinking cup, which was not filled to the 120 ml level, and then administered the contents via the feeding tube. She stated this was her usual method for administering the resident’s tube feedings. Record review and subsequent measurement of the formula bottles by the DON showed that each bottle contained 1,000 ml and that the bottle used for the observed feeding had been opened the previous day before the resident’s 5:00 PM feeding. The feeding observed was the fifth feeding from that bottle, and based on the ordered regimen, the bottle should have been depleted and an additional 200 ml from a new bottle should have been required if the correct volumes had been administered at each feeding. Instead, only approximately 60 ml from the new bottle was used, indicating that the resident’s tube feeding at that time was short by about 140 ml. The DON confirmed that the resident did not receive the correct amount of tube feeding formula as ordered by the physician and that nurses were expected to use the provided syringe to accurately measure tube feeding volumes, consistent with the facility’s enteral nutrition policy, which requires administering the ordered amount of feeding.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0693 citations
Incorrect G-tube Flush Volume During Enteral Feeding
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

Incorrect G-tube Flush Volume During Enteral Feeding: A resident with severe cognitive impairment, aphasia, stroke, hemiplegia, and a feeding tube was observed receiving enteral feeding when an RN flushed the G-tube with 30 ml of water before and after the feeding instead of the ordered 60 ml. The RN stated he read the order wrong, and the DON and ADON confirmed the correct flush amount should have been followed.

Fine: $9,821
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Provide Ordered Hydration and Correct Tube Flushes for Enteral Feeding
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with moderate cognitive impairment, multiple comorbidities, and NPO status received nutrition and hydration via a gastrojejunal tube with orders for continuous tube feeding, 30 mL water flushes before and after medications via the gastric port, 120 mL free water flushes six times daily, and 30 mL jejunal port flushes every four hours. During observed care, an LPN administered medications and 30 mL water flushes through the gastric port but did not provide the ordered 120 mL free water flush or the 30 mL jejunal port flush, and no additional flushes were given over several hours. Later, another LPN initially attempted to give medications through the jejunal port before being redirected, and documentation on the MAR/TAR showed inconsistent flush volumes of 30–60 mL instead of the ordered 120 mL free water flushes, reflecting failure to consistently implement the prescribed hydration and port-specific flushing regimen.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Improper Head-of-Bed Positioning During Tube Feeding
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident receiving enteral tube feeding was observed lying with the HOB elevated only 15 degrees while Glucerna was infusing at 60 ml/hr. An LVN started the feeding and was unsure of the correct HOB position, and an RN stated the HOB was not elevated properly to prevent aspiration. Records showed an order to keep the HOB elevated 30-45 degrees or as tolerated and a care plan noting tube feeding related to dysphagia.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
GT Site Care and Feeding Position Not Provided as Ordered
E
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

GT site care and feeding precautions were not followed for two residents with GTs. One resident with dementia and severe cognitive impairment had a GT dressing left unchanged despite orders for daily cleansing and dressing changes, and drainage was observed at the site. Another resident was observed lying flat in a supine position while receiving continuous GT feeding, even though the CP and OSR required HOB elevation during tube feeding; RN and DON confirmed the ordered positioning was not being followed.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Expired Tube Feeding Formula Left Connected to Resident
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

Expired Tube Feeding Formula Left Connected to a Resident: A resident with anoxic brain damage, dysphagia, and a gastrostomy tube was observed with an enteral feeding pump off but still connected and a tube feeding bag that staff said had exceeded the 24-hour limit after opening. Staff confirmed the formula was no longer safe after 24 hours, and the facility policy required accurate labeling and dating of each feeding bag or formula container.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
GT Not Flushed Before Medication Administration
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

GT Not Flushed Before Med Pass: An LPN was observed preparing to give crushed meds through a resident’s GT without first flushing the tube with water. The surveyor stopped the med pass before any meds were given, and both the LPN and DON confirmed the GT had not been flushed as required by the resident’s order and facility policy.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Know what gets cited — and walk into your next survey with full visibility

We process and analyze inspection reports and Plans of Correction using AI to surface insights and trends — so you can improve care quality and stay ahead of compliance risk before your next survey.

Get ready for your next survey

See what surveyors are citing in your state and spot your risk areas before they do.

Monthly Citation Reports

Have you been cited for this tag?

Save hours drafting a compliant Plan of Correction — AI built on real approved POCs.

Plan of Correction Writer

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release June 24, 2026) and official state health department websites — never guesswork.

Trusted by long-term care providers and associations.

Allegria Senior Living logo
FHCA logo
WeCare Centers logo
Care Rehab logo
An unhandled error has occurred. Reload 🗙