F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
D

Failure to Provide Ordered Enteral Nutrition and Accurately Document Tube Feeding Intake

Bria Of Elmwood ParkElmwood Park, Illinois Survey Completed on 01-11-2026

Summary

The deficiency involves the facility’s failure to ensure that residents who were unable to maintain adequate nutrition independently received enteral nutrition as ordered and that accurate records of daily enteral intake were maintained. Three nonverbal, fully dependent residents with gastrostomy tubes and significant medical conditions, including anoxic brain damage, respiratory failure, severe protein-calorie malnutrition, tracheostomy status, and pressure ulcers, were affected. For one resident, the spouse reported that the feeding tube pump was off when she arrived around 6:00 PM, despite orders for continuous tube feeding from 2:00 PM to 11:00 AM. Nursing documentation and an incident narrative confirmed that the feeding tube had been turned off for several hours, resulting in missed scheduled tube feeding, and that the issue was brought to staff attention by the spouse. The telehealth physician note further documented that the spouse was upset that feeds were not running between 2:00 PM and 6:00 PM and that feeds were only started once the notification was made. The same resident’s family member reported that this problem had occurred multiple times over a period of weeks, including around Thanksgiving and Christmas, stating that the resident had not been fed for 6 to 8 hours on separate occasions. The family member also reported another recent visit when the pump was beeping and displayed “INACTIVE,” and the nurse present, identified as agency staff, could not explain why the feeding was not running. A CNA stated that when he goes in to provide care, the feeding is often paused and the nurse is notified to turn it back on. At the time of surveyor observation, the resident’s feeding pump was running at the ordered rate of 50 mL/hr with a labeled start time of 6:00 AM, but the amount of formula remaining in the container and the total volume displayed on the pump did not match what should have infused based on the documented start time and rate. For the second resident, who was also nonverbal and fully dependent with diagnoses including respiratory failure, hemiplegia, severe protein-calorie malnutrition, anoxic brain damage, tracheostomy status, and gastrostomy status, the physician’s order specified Jevity 1.5 at 80 mL/hr continuous for 20 hours, on at 2:00 PM and off at 10:00 AM or until 1600 mL was infused, with water flushes every 6 hours. During surveyor observation, the feeding pump was running at 80 mL/hr, but the feeding container lacked a start time label, and approximately 900 mL remained in a 1000 mL container when, based on the ordered rate and start time, only about 100 mL should have remained. The total fed volume on the pump (209 mL) also did not correspond to the actual volume in the container, and the absence of a start time made it unclear when the feeding had been started or whether it had been running continuously as ordered. For the third resident, who was nonverbal, fully dependent, and had diagnoses including anoxic brain damage, chronic respiratory failure, tracheostomy status, compression of the brain, dependence on supplemental oxygen, and gastrostomy status, the physician’s order specified Vital 1.5 at 70 mL/hr continuous for 21 hours, on at 2:00 PM and off at 11:00 AM, with a total daily volume of 1470 mL and water flushes every 6 hours. Surveyors observed the feeding pump running at 70 mL/hr with a labeled start time of 3:00 AM, and approximately 600 mL remaining in a 900 mL container. Based on the ordered rate and the labeled start time, the container should have contained about 480 mL, but the observed volume did not match this calculation. The total fed volume displayed on the pump was 2836 mL, which exceeded the ordered daily volume of 1470 mL and did not correspond to the labeled start time. The DON acknowledged that staff may not have reset the pump when hanging a new bottle and confirmed that nurses should reset the machine at that time. Across all three residents, review of the medical records showed no documentation of when tube feedings were interrupted, stopped, or restarted, and there was no accurate record of the total daily volume of tube feeding delivered. The DON stated that there was no flow sheet to track bottle changes and that documentation was limited to the MAR, which for one resident showed tube feedings as administered but without times for when feedings were started or total volume received. The facility’s own tube feeding guideline required that the pump be cleared at the end of each shift and that tube feeding delivered be documented, but the observed discrepancies between ordered rates, labeled start times, pump volumes, and actual formula remaining, along with missing documentation of interruptions and total intake, demonstrate that these procedures were not followed for the residents reviewed.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0693 citations
Incorrect G-tube Flush Volume During Enteral Feeding
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

Incorrect G-tube Flush Volume During Enteral Feeding: A resident with severe cognitive impairment, aphasia, stroke, hemiplegia, and a feeding tube was observed receiving enteral feeding when an RN flushed the G-tube with 30 ml of water before and after the feeding instead of the ordered 60 ml. The RN stated he read the order wrong, and the DON and ADON confirmed the correct flush amount should have been followed.

Fine: $9,821
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Provide Ordered Hydration and Correct Tube Flushes for Enteral Feeding
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with moderate cognitive impairment, multiple comorbidities, and NPO status received nutrition and hydration via a gastrojejunal tube with orders for continuous tube feeding, 30 mL water flushes before and after medications via the gastric port, 120 mL free water flushes six times daily, and 30 mL jejunal port flushes every four hours. During observed care, an LPN administered medications and 30 mL water flushes through the gastric port but did not provide the ordered 120 mL free water flush or the 30 mL jejunal port flush, and no additional flushes were given over several hours. Later, another LPN initially attempted to give medications through the jejunal port before being redirected, and documentation on the MAR/TAR showed inconsistent flush volumes of 30–60 mL instead of the ordered 120 mL free water flushes, reflecting failure to consistently implement the prescribed hydration and port-specific flushing regimen.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Improper Head-of-Bed Positioning During Tube Feeding
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident receiving enteral tube feeding was observed lying with the HOB elevated only 15 degrees while Glucerna was infusing at 60 ml/hr. An LVN started the feeding and was unsure of the correct HOB position, and an RN stated the HOB was not elevated properly to prevent aspiration. Records showed an order to keep the HOB elevated 30-45 degrees or as tolerated and a care plan noting tube feeding related to dysphagia.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
GT Site Care and Feeding Position Not Provided as Ordered
E
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

GT site care and feeding precautions were not followed for two residents with GTs. One resident with dementia and severe cognitive impairment had a GT dressing left unchanged despite orders for daily cleansing and dressing changes, and drainage was observed at the site. Another resident was observed lying flat in a supine position while receiving continuous GT feeding, even though the CP and OSR required HOB elevation during tube feeding; RN and DON confirmed the ordered positioning was not being followed.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Expired Tube Feeding Formula Left Connected to Resident
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

Expired Tube Feeding Formula Left Connected to a Resident: A resident with anoxic brain damage, dysphagia, and a gastrostomy tube was observed with an enteral feeding pump off but still connected and a tube feeding bag that staff said had exceeded the 24-hour limit after opening. Staff confirmed the formula was no longer safe after 24 hours, and the facility policy required accurate labeling and dating of each feeding bag or formula container.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
GT Not Flushed Before Medication Administration
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

GT Not Flushed Before Med Pass: An LPN was observed preparing to give crushed meds through a resident’s GT without first flushing the tube with water. The surveyor stopped the med pass before any meds were given, and both the LPN and DON confirmed the GT had not been flushed as required by the resident’s order and facility policy.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Know what gets cited — and walk into your next survey with full visibility

We process and analyze inspection reports and Plans of Correction using AI to surface insights and trends — so you can improve care quality and stay ahead of compliance risk before your next survey.

Get ready for your next survey

See what surveyors are citing in your state and spot your risk areas before they do.

Monthly Citation Reports

Have you been cited for this tag?

Save hours drafting a compliant Plan of Correction — AI built on real approved POCs.

Plan of Correction Writer

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release June 24, 2026) and official state health department websites — never guesswork.

Trusted by long-term care providers and associations.

Allegria Senior Living logo
FHCA logo
WeCare Centers logo
Care Rehab logo
An unhandled error has occurred. Reload 🗙