F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
J

Failure to Ensure Safe Mechanical Lift Transfer Results in Resident Fall and Fracture

Three Links Care CenterNorthfield, Minnesota Survey Completed on 09-19-2025

Summary

A deficiency occurred when staff failed to ensure safe transfers for a resident using a full body mechanical lift. Two nursing assistants were involved in transferring a resident who was dependent on staff for all transfers and had significant medical conditions, including a recent femur fracture, artificial hip joint, hemiplegia, and hemiparesis. During the transfer, the nursing assistants did not follow the manufacturer's recommendations for the lift and did not properly attach the sling, specifically using different length black loops on each side of the sling, which caused slack and led to the sling detaching from the lift arm. The resident slipped out of the improperly secured sling and fell from an elevated height, striking his head on the ground. The incident resulted in a new fracture of the right femur, requiring hospitalization and surgical intervention. Documentation and interviews confirmed that the nursing assistants were aware that the same length loops should be used but failed to ensure this during the transfer. Additionally, they had not received specific training on the type of sling used for this resident, which had two sets of black loops that could be easily confused. The facility's policies required staff to use appropriate techniques and processes when utilizing mechanical lifts and to conduct root cause analyses following falls. However, the staff involved did not adhere to these protocols, and the lack of specific training on the sling contributed to the incident. The root cause was identified as the use of different length loops, which led to the release of tension and the resident's fall.

Removal Plan

  • R1 will be reassessed on return from the hospital for proper sling size and care plan updated.
  • Sling and lift used for R1's transfer was removed from use until inspected and found to be free of malfunction.
  • NA-A and NA-B had return demonstration competency testing done for safe lifting using the mechanical lift.
  • The facility reviewed their policy and procedure for safe mechanical lift transfers and developed a plan to ensure identification via color coding the sling loops to ensure the correct one being used. Policy will be adjusted after mechanical lift representative reviews policy, if needed.
  • All residents utilizing similar slings like R1 have had the proper sling to use marked with the colored tape to identify the same loops.
  • All residents who utilized the mechanical lifts had slings inspected, care plans reviewed to ensure the proper sling size in the care plan.
  • The facility began re-education with return demonstration, to nursing staff on manufacturer's recommendations of using the full body mechanical lift to include checking the straps for tension and using proper sling size according to the care plan and will be having mechanical lift representative provide education to all of the nursing staff.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0689 citations
Failure to Control Razors, Sharps, and Chemical Wipes Creating Accident Hazards
D
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

Surveyors found that the facility failed to keep the environment free of accident hazards when a resident’s room contained an unattended shaving razor on the sink and additional razors in a nightstand, despite leadership stating razors were not permitted in resident rooms. An LPN disposed of unused lancets in regular trash instead of a sharps container, contrary to acknowledged policy. On two occasions, an unattended housekeeping cart on an upper floor had germicidal wipes left on top and easily accessible, even though housekeeping leadership and staff stated that chemicals and disinfectant wipes were to be kept locked in the cart for safety.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Assess Safe Use of Lift Reclining Chair
D
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

A resident with severe cognitive impairment, dementia, a history of falls, and dependence on staff for transfers was observed using a lift reclining chair even though the care plan and physical device review did not identify that device. Therapy staff lowered the chair and placed the remote next to the call light on the resident’s lap, and staff stated they were not aware of any formal assessment for safe use of the lift chair. The DON stated the resident should have had an assessment to determine whether she was safe to have the lift chair.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Follow Transfer and Sling Size Interventions
D
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

A resident with severe cognitive impairment, dementia with behavioral disturbances, and fall risk interventions in place was transferred by staff using methods that did not match the care plan and Kardex. Staff used a transfer belt for some transfers, then later used a Hoyer lift from mattresses on the floor to a wheelchair, but used a green sling even though the resident required a yellow sling based on weight. The RN, LPN, DON, and PT verified the resident’s transfer status and sling instructions were not updated to reflect current needs.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Complete Required Quarterly Smoking Safety Assessments
D
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

A resident with nicotine dependence was care planned as a smoker who could go out to smoke at designated times or with family, with an intervention that a smoking evaluation be completed quarterly. The last documented smoking safety evaluation showed the resident could safely smoke with supervision, but no additional evaluations were completed for several months, contrary to facility policy requiring smoking assessments at admission, readmission, with significant change, and quarterly by a licensed nurse, even though the resident continued to smoke under staff and family supervision in the courtyard.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Supervise Smokers and Secure Smoking Materials
J
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

Failure to supervise smokers and secure smoking materials. Surveyors found that 27 smokers were not adequately monitored and that residents were able to keep cigarettes and lighters in their possession despite care plan directions to return them after smoking. One resident with severe cognitive impairment, dementia, schizophrenia, and continuous oxygen use was observed with cigarettes and a lighter while on oxygen, and staff confirmed she was an unsafe smoker requiring direct supervision.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Code Alert System Failed to Prevent Resident Elopement
J
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

Code Alert System Failed to Prevent Resident Elopement: The facility failed to keep the code alert system functioning as intended and did not follow the manufacturer’s weekly testing and inspection guidance. Two residents with significant cognitive impairment were able to get through the main doors, and one resident exited the building before staff followed outside. The report also states that multiple residents with code alert devices did not have adequate elopement or wandering assessments and care plan interventions, and several attempts to leave were not documented in the record.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Minnesota

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Minnesota — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release August 26, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.