F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
D

Failure to Provide Scheduled Toileting and Appropriate Catheter Care

Altercare Of Cuyahoga Falls Ctr For Rehab & NursinCuyahoga Falls, Ohio Survey Completed on 06-12-2025

Summary

The facility failed to provide scheduled toileting and promote continence for a resident who was cognitively intact and able to request assistance. Despite physician orders for prompted toileting and a care plan indicating the resident was a candidate for a prompted bowel program, staff did not assist or encourage the resident to use the bathroom or a bedside commode. The resident reported long waits for assistance, lack of access to a bathroom or commode, and being placed in briefs instead of being helped to the toilet. Observations confirmed the absence of a bedside commode and that staff routinely performed 'check and change' care rather than scheduled toileting. Therapy staff indicated the resident was capable of using the bathroom with minimal assistance, but there was a lack of communication between therapy and nursing staff regarding the resident's toileting abilities and needs. The required clinical admission assessment to identify bowel and bladder needs was not completed upon readmission, and staff relied on previous assessments without updating the care plan based on current needs. Another resident with an indwelling catheter and a history of urinary retention and uropathy did not receive appropriate catheter care to prevent and treat urinary tract infections (UTIs). The resident was dependent on staff for toileting and hygiene and had a care plan that included assistance with incontinence care and application of moisture barrier cream. However, there was no documentation of urinalysis or monitoring of urinary symptoms prior to the resident being hospitalized for a UTI. The resident reported being left in soiled briefs and with a full catheter bag for extended periods, leading to her calling the police for assistance. Hospital records confirmed the presence of a UTI, and interviews with staff corroborated that the resident's catheter bag was sometimes left full and leaking, with staff failing to document or report abnormal urine appearance or odor as required by facility policy. Interviews with staff revealed inadequate communication, insufficient documentation, and a lack of adherence to facility policies regarding restorative nursing care and catheter care. Staff did not consistently monitor or report changes in residents' urinary status, and there was a failure to ensure timely and appropriate toileting and incontinence care. These deficiencies resulted in residents not receiving the necessary care and services to promote continence and prevent urinary tract infections.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0690 citations
Missing Orders and Documentation for Condom Catheter Drainage Bag Care
D
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

A resident with intact cognition and multiple diagnoses, including BPH and stroke, had a physician order for a condom catheter at bedtime, but the EMR lacked orders or instructions for cleaning, disinfecting, monitoring, or changing the drainage bag. During observation, the bag was seen hanging in the bathroom, and an LPN, RN case manager, and DON all confirmed the absence of documented guidance for the catheter drainage bag care.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Incomplete Suprapubic Catheter Orders and Care Coordination
D
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

A resident with a suprapubic catheter had incomplete orders and unclear care coordination. The care plan did not identify the SP catheter or who was responsible for catheter care and bag changes, and the MAR/TAR contained repeated orders to clarify catheter size without a documented size in the orders. Staff interviews showed uncertainty about the catheter size, who would change the catheter, and whether the listed contact number was available at all times.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Maintain Proper Indwelling Catheter Care and Bag Positioning
D
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

Surveyors found that two residents with indwelling urinary catheters did not receive care consistent with their care plans, physician orders, or facility policy. Catheter collection bags were repeatedly observed resting directly on the floor when residents were in bed or seated, and the bags were not contained in basins as specified for one resident. Required catheter care every shift was not documented, and an LPN reported that a catheter bag hung on a recliner had slipped down. The facility’s written policy required keeping catheter bags below bladder level and off the floor, as well as providing routine hygiene, but these standards were not followed.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Provide and Document Catheter Care
H
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

The facility failed to provide and document catheter care for multiple residents with Foley or suprapubic catheters. A resident with a suprapubic catheter developed drainage, vomiting, and sepsis secondary to CAUTI, while other residents had repeated catheter pain, pus, blockage, hematuria, UTIs, and hospital transfers, including ICU admission for septic shock. The record showed no catheter care orders or task documentation for several residents, and the NHA and DON confirmed the missing documentation.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Catheter Drainage Bag Allowed to Touch Floor, Breaching Infection Control
D
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

A resident receiving short-term rehab with an indwelling urinary catheter was observed in a wheelchair with the catheter drainage bag hung under the seat and touching the floor, despite facility documentation requirements that staff verify each shift that privacy bags are in place and drainage bags are not on the floor. An RN confirmed that catheter bags are not supposed to touch the floor, indicating a failure to follow established catheter care and infection control practices.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Indwelling Catheter Drainage System Left on Floor
D
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

Indwelling Catheter Drainage System Left on Floor: A resident with CKD and a UTI had an indwelling urinary catheter, but staff observed the catheter tubing and drainage bag on the floor on multiple occasions. An LPN also lifted the bag above the level of the bladder while repositioning it, and staff interviews confirmed the bag and tubing should not touch the floor.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Ohio

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Ohio — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release August 26, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.