F0880 F880: Provide and implement an infection prevention and control program.
D

Failure to Implement Infection Control and Hand Hygiene Practices During Resident Care

Salem Lutheran HomeElk Horn, Iowa Survey Completed on 06-26-2025

Summary

Staff failed to implement appropriate infection prevention and control practices during care for two residents with indwelling medical devices and wounds. For one resident with an indwelling catheter, a CNA donned gown and gloves without performing hand hygiene, placed a urine graduate on a barrier on the floor, and emptied the catheter drainage bag without cleaning the drainage port beforehand. The drainage port was only cleansed with an alcohol wipe after the bag was emptied, and the CNA left the room without performing hand hygiene. Both the Infection Preventionist and the Director of Nursing confirmed that hand hygiene should be completed and Enhanced Barrier Precautions (EBP) should be used at appropriate times during catheter and wound care, as outlined in facility policy. Another resident with multiple chronic conditions, including venous and arterial ulcers, required frequent wound care to both lower extremities. During wound care, an LPN demonstrated inconsistent hand hygiene, such as removing gloves and donning new ones without hand hygiene, and did not always use a gown when applying dressings to the buttocks. The LPN also failed to maintain a clean and dirty environment, placing opened bandages on her lap and under her arm, and continued to use supplies that had fallen on the floor without changing gloves or performing hand hygiene. Dressings were not dated, and the LPN was observed to request assistance from the Infection Preventionist, who had to don PPE to assist. Facility policies required adherence to the 4 Moments of Hand Hygiene and the use of EBP for residents with indwelling devices or wounds, including the use of gloves and gowns during high-contact care activities. Observations and interviews revealed that staff did not consistently follow these protocols, leading to lapses in infection control practices for both residents. The Director of Nursing and Infection Preventionist acknowledged these deficiencies, noting failures in hand hygiene, PPE use, and maintenance of clean and dirty technique during resident care.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0880 citations
Failure to Follow Enhanced Barrier Precautions During Wound Care
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

A resident with a chronic heel wound with drainage, classified as high risk under the facility’s Enhanced Barrier Precautions (EBP) policy, received wound care from a Wound Nurse and a NA who wore masks and gloves but did not don gowns during multiple high-contact wound care activities on both lower extremities. The facility’s EBP policy requires both gloves and gowns for high-contact care, including wound care, for residents with chronic wounds. At the time of care, there was no EBP sign on the door and no PPE caddie or supplies outside the room. In subsequent interviews, the Wound Nurse and NA reported they did not wear gowns because there was no sign on the door and the nurse was not wearing one, while the IP and DON stated they would have expected gown use and confirmed that wound care is considered a high-contact activity under the policy.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Implement and Follow Enhanced Barrier Precautions During Wound Care
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Staff failed to consistently implement and follow Enhanced Barrier Precautions (EBP) during wound care for two residents. For a resident with an indwelling urinary catheter and an EBP order, an RN and a CNA removed their gowns after catheter care and performed a heel and toe dressing change wearing only gloves, despite a door sign requiring gown and gloves for wound care and other high-contact care. For another resident with multiple open leg wounds and active wound care orders, an RN and a nurse aide performed dressing changes with gloves only, without gowns, and there was no EBP signage or order in place. Interviews with nursing staff, the IP, and the DON revealed inconsistent understanding and application of the facility’s EBP policy, which requires gown and gloves for high-contact care activities, including wound care and device care, for residents with chronic wounds or indwelling devices.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Incomplete COVID Surveillance and Return-to-Work Tracking
F
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

The facility failed to fully document infection surveillance and RTW decisions during a COVID outbreak. Multiple staff members reported symptoms such as sore throat, headache, congestion, diarrhea, vomiting, fever, and cough, but the employee illness logs were incomplete and left the RTW date blank, with no indication they were tested for COVID or cleared per CDC guidance. At the same time, multiple residents were diagnosed with COVID and others had GI symptoms with unknown testing status. The IP said she worked infection control only a few hours per week and had not thoroughly reviewed the logs for trends, while the DON had not been reviewing the surveillance logs.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Cross Contamination During Dressing Change and Infection Control Program Deficiencies
E
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Cross contamination occurred during a dressing change when an LPN placed a resident’s foot directly on the wheelchair seat without a barrier and did not clean the bedside table after the procedure. The facility also lacked infection surveillance documentation for several months, and its Legionella water management plan was incomplete, with no mapping of high-risk areas, no temperature logs, and no documented preventive measures for unused areas.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Infection Control Failures During Resident Care
E
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Infection Control Failures During Resident Care: Staff did not follow PPE, hand hygiene, and equipment-cleaning practices during care for several residents. An RN failed to clean a glucometer and basket after blood sugar checks, a CNA and a Central Supply staff member entered rooms with enhanced barrier precautions without PPE, and an LVN did not clean the glucometer or insulin vial, and did not properly perform hand hygiene during insulin administration and after emptying a urinal. Residents involved had significant cognitive impairment, diabetes, wounds, and other serious diagnoses.

Inspection fine: $27,378
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Infection Control Lapses in Laundry Services and Policy Review
F
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Infection control failed during laundry services when staff reported using the same personal T-shirt for handling dirty laundry and then hanging clean laundry, while using disposable gowns only for laundry from a resident with an infection. The DON also acknowledged that the Infection Prevention Program policy was overdue for annual review, and the policy showed no indication of an annual review.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Iowa

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Iowa — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release August 26, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.