F0658 F658: Ensure services provided by the nursing facility meet professional standards of quality.
D

Failure to Consistently Monitor and Document Vitals and Neuro Checks After Resident Fall

Wellbridge Of ClarkstonClarkston, Michigan Survey Completed on 05-15-2025

Summary

A deficiency occurred when the facility failed to ensure that a resident received complete and accurate vital sign monitoring and documentation per physician orders and professional standards of practice. The resident, who had Alzheimer's disease, diabetes, and hypertension, was on two blood thinners (Plavix and Eliquis) and a blood pressure medication (Metoprolol Tartrate). After experiencing a fall in the bathroom and hitting her head, the resident was found with a bump on her head and a skin tear on her right arm. The nurse initiated neuro checks and contacted the provider, but there was no detailed documentation of the head wound in the medical record, and the neuro check documentation was not initially found in the electronic medical record (EMR). Further review revealed that the resident's blood pressure readings were not consistently documented prior to the administration of Metoprolol, as required by physician orders. The Medication Administration Record (MAR) showed the medication was given twice daily, but blood pressure readings were only recorded five times over a two-week period, despite 29 opportunities. This lack of consistent monitoring made it impossible to determine if low blood pressure contributed to the resident's fall. Additionally, the neuro check documentation began 15 minutes after the fall, and vital signs at the time of the fall were not initially available in the EMR. A paper copy of the neuro check sheet with hand-written vitals was later produced, but it had not been previously scanned or included in the EMR. Interviews with nursing staff and the Director of Nursing (DON) confirmed that vital sign monitoring was not consistently performed or documented as required. The DON acknowledged the absence of a detailed skin assessment and the incorrect entry of older vital signs in the change of condition form. The facility's policies required vital sign monitoring prior to medication administration and neurological assessment after falls with suspected head trauma, but these standards were not met in this case.

Plan Of Correction

1.) Resident #64 was assessed and no acute issues were noted. All residents have the potential to be affected. 2.) A one-time review of all guests on hypertensive medications from the last 30 days was completed to ensure hypertensive parameters are being followed. A one-time review of falls within the last 14 days was reviewed to ensure neuro checks were being completed as ordered. 3.) Licensed nurses were re-educated on following parameters on hypertensive medications and on completing neuro checks with unwitnessed falls. System change: The nurse managers will review all new hypertensive medications for parameters if needed and will review all falls to ensure neuro checks were completed for unwitnessed falls. 4.) DON/Designee will review 5 medical records weekly x 12 weeks to ensure that hypertensive medications with parameters are being followed. Any non-adherence will result in 1:1 education. All audits will be taken to the QA committee for review. DON/Designee will review 5 medical records weekly x 12 weeks to ensure that neuro checks were being completed for unwitnessed falls. Any non-adherence will result in 1:1 education. All audits will be taken to the QA committee for review. 5.) The Executive Director is responsible for maintaining compliance with the regulation.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0658 citations
Missing Physician Order and Care Plan Update for New Wrist Splint
D
F0658 F658: Ensure services provided by the nursing facility meet professional standards of quality.
Short Summary

A resident with a fractured wrist returned from an orthopedic visit wearing a new black wrist splint after the cast was removed, but the clinical record lacked an updated physician order and instructions for splint use and care. Staff also did not document follow-up with the physician, and the care plan was not revised when the splint began being used; the DON acknowledged the missing order and lack of a policy for obtaining updated physician information.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Wrong Opioid Dose Administered After Order Change
D
F0658 F658: Ensure services provided by the nursing facility meet professional standards of quality.
Short Summary

A resident with peripheral vascular disease and a left above-knee amputation, who was moderately cognitively impaired and receiving PRN opioid analgesia for pain, had a Hydrocodone/Acetaminophen order changed from 10 mg/325 mg to 5 mg/325 mg every 6 hours PRN. The MAR for the month showed both the discontinued 10 mg/325 mg order and the new 5 mg/325 mg order, and review of the controlled substance declining count sheets revealed that nurses repeatedly removed 10 mg/325 mg tablets while documenting administration of 5 mg/325 mg on the MAR, and on two occasions removed 10 mg/325 mg tablets with no corresponding MAR entry. The NP confirmed the resident should have been receiving only the 5 mg/325 mg dose during this period, and the DON stated the discontinued 10 mg/325 mg supply and count sheet should have been removed when the order was changed.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Administration and Ordering Did Not Meet Professional Standards
D
F0658 F658: Ensure services provided by the nursing facility meet professional standards of quality.
Short Summary

Medication administration and ordering did not meet professional standards when an LPN incorrectly held an antihypertensive despite the BP parameter, disposed of an unadministered tablet in a resident’s room trash instead of using approved disposal methods, and failed to instruct a resident to rinse their mouth after a Breyna inhaler as ordered. Additionally, two PRN bowel medications for a resident with a colostomy were ordered for rectal administration, even though, according to an RN, this resident could not receive medications rectally.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Complete Neuro Checks, Alert Charting, and Skin Assessments After Falls and Abuse Allegation
E
F0658 F658: Ensure services provided by the nursing facility meet professional standards of quality.
Short Summary

A resident with a history of traumatic brain injury and multiple falls did not receive complete neurological checks, skin assessments, or shift‑by‑shift alert charting as required by facility policy after several falls, including events with head impact and documented abnormal pupil findings that were never reported to a physician. Documentation shows missed neuro‑check intervals, discontinued monitoring before the 72‑hour period ended, and no internal records of head and facial injuries later described in hospital records. In a separate incident, two cognitively intact residents involved in a resident‑to‑resident altercation, where one kicked the other’s knee, were placed on 72‑hour alert charting, but nursing staff failed to complete alert charting every shift as ordered. Interviews with nursing leadership and other staff confirmed that these monitoring and documentation expectations were not met and that required physician notification for neurological changes did not occur.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Prolonged Administration of Incorrect Divalproex Dose Due to Pharmacy and Nursing Verification Failures
E
F0658 F658: Ensure services provided by the nursing facility meet professional standards of quality.
Short Summary

A resident with an order for Divalproex DR 250 mg, two tablets in the morning and three at bedtime, was instead given 500 mg tablets over an extended period after the contracted pharmacy dispensed the wrong strength. The MAR continued to reflect the 250 mg order and was signed daily as given, while nurses did not detect that the medication cards contained a different strength than the physician’s order. The resident later developed altered mental status and was sent to the ER, and a NP documented that the resident had been receiving the incorrect Divalproex dose. Staff interviews and facility policy confirmed that nurses were expected to verify the right dose by comparing the medication label to the MAR and order, but this verification process failed in this case.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Follow Ordered Urology Consultation
D
F0658 F658: Ensure services provided by the nursing facility meet professional standards of quality.
Short Summary

Failure to Follow Ordered Urology Consultation: A resident with urinary retention and a Foley catheter had a physician order for urology referral after a failed trial without catheter, but the consultation was not completed. An LPN knew the resident was supposed to be seen by urology but did not know why it had not happened, and the DON and ADON/IP stated the physician was expected to make the referral and that the status was not discussed in later monthly rounds.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Know what gets cited — and walk into your next survey with full visibility

We process and analyze inspection reports and Plans of Correction using AI to surface insights and trends — so you can improve care quality and stay ahead of compliance risk before your next survey.

Get ready for your next survey

See what surveyors are citing in your state and spot your risk areas before they do.

Monthly Citation Reports

Have you been cited for this tag?

Save hours drafting a compliant Plan of Correction — AI built on real approved POCs.

Plan of Correction Writer

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release June 24, 2026) and official state health department websites — never guesswork.

Trusted by long-term care providers and associations.

Allegria Senior Living logo
FHCA logo
WeCare Centers logo
Care Rehab logo
An unhandled error has occurred. Reload 🗙