F0880 F880: Provide and implement an infection prevention and control program.
D

Deficiencies in Infection Control and Isolation Precautions

Terrace Of St Cloud, TheSaint Cloud, Florida Survey Completed on 04-24-2025

Summary

Surveyors identified deficiencies in the facility's infection prevention and control practices. In one instance, a resident placed on contact isolation for a staph infection had a biohazard waste receptacle for used personal protective equipment (PPE) located in the middle of the room, between the beds of two residents. This placement required staff to walk past the resident's bed and dresser to dispose of soiled PPE, rather than having the disposal container near the exit as required by facility policy and standard infection control practices. The infection preventionist confirmed that this setup constituted a break in isolation protocol, as it increased the risk of transmitting the organism to other residents. Another deficiency was observed during medication administration for a resident with diabetes and other medical conditions. An LPN performed a blood glucose check and administered an injectable medication without donning gloves, despite the potential for exposure to blood. The LPN also failed to sanitize his hands before and after the procedure and did not clean the glucometer before placing it back into the medication cart. The Director of Nursing confirmed that the facility's policy required the use of gloves and cleaning of equipment between residents, and acknowledged that the LPN did not follow these procedures. Facility policies reviewed by surveyors indicated that staff were required to wear gloves during procedures involving potential exposure to blood or body fluids, and to clean reusable equipment after each use. The observed failures to adhere to these policies during both isolation precautions and medication administration led to the cited deficiencies in infection prevention and control.

Plan Of Correction

F 880 A) What corrective action will be accomplished for these residents found to be effective: On Resident #56, biohazard waste receptacle for used PPE was moved to the appropriate location near the exit of the resident's room. On Resident #64, was assessed and no adverse side effects were noted at that time. On LPN A, received education from the ADON on appropriate handwashing, appropriate use of PPE, isolation precautions, and how to appropriately clean multi-use items. B) How will you identify other residents having potential to be affected and what corrective actions will be taken: All residents with isolation precautions or who require monitoring. On no other residents were able to be identified upon review of LPN A's assigned residents. On LPN A, received education from the ADON on appropriate handwashing, appropriate use of PPE, isolation precautions, and how to appropriately clean multi-use items. On the ADON, initiated education for all licensed nurses on appropriate handwashing, appropriate use of PPE, isolation precautions, and how to appropriately clean multi-use items. On biohazard waste receptacles in isolation rooms were moved to the appropriate location near the exit of the resident rooms. Staff have been educated on the appropriate placement of the waste receptacles. C) What measures will be put in place or what system change will be made to ensure this will not recur: On LPN A, received education from the ADON on appropriate handwashing, appropriate use of PPE, isolation precautions, and how to appropriately clean multi-use items. On the ADON, initiated education for all licensed nurses on appropriate handwashing, appropriate use of PPE, isolation precautions, and how to appropriately clean multi-use items. On staff, initiated education on handwashing, implementation of appropriate isolation precautions, and appropriate use of PPE. On biohazard waste receptacles in isolation rooms were moved to the appropriate location near the exit of the resident rooms. Staff have been educated on the appropriate placement of the waste receptacles. The Unit Managers, or designee, will randomly audit, 3 times a week, across all shifts, staff handwashing, implementation of appropriate isolation precautions, appropriate placement of biohazard waste receptacles, medication administration for appropriate use of PPE, and use and cleaning of multi-use items. Audits will be submitted to the DON weekly. Any identified problems will be addressed immediately. D) How the corrective action will be monitored to ensure the potential will not occur: The DON, or designee, will report the findings of the audits to the QA and QAPI committees monthly for 3 months, then quarterly for 4 quarters.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0880 citations
Failure to Follow Enhanced Barrier Precautions During Wound Care
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

A resident with a chronic heel wound with drainage, classified as high risk under the facility’s Enhanced Barrier Precautions (EBP) policy, received wound care from a Wound Nurse and a NA who wore masks and gloves but did not don gowns during multiple high-contact wound care activities on both lower extremities. The facility’s EBP policy requires both gloves and gowns for high-contact care, including wound care, for residents with chronic wounds. At the time of care, there was no EBP sign on the door and no PPE caddie or supplies outside the room. In subsequent interviews, the Wound Nurse and NA reported they did not wear gowns because there was no sign on the door and the nurse was not wearing one, while the IP and DON stated they would have expected gown use and confirmed that wound care is considered a high-contact activity under the policy.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Implement and Follow Enhanced Barrier Precautions During Wound Care
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Staff failed to consistently implement and follow Enhanced Barrier Precautions (EBP) during wound care for two residents. For a resident with an indwelling urinary catheter and an EBP order, an RN and a CNA removed their gowns after catheter care and performed a heel and toe dressing change wearing only gloves, despite a door sign requiring gown and gloves for wound care and other high-contact care. For another resident with multiple open leg wounds and active wound care orders, an RN and a nurse aide performed dressing changes with gloves only, without gowns, and there was no EBP signage or order in place. Interviews with nursing staff, the IP, and the DON revealed inconsistent understanding and application of the facility’s EBP policy, which requires gown and gloves for high-contact care activities, including wound care and device care, for residents with chronic wounds or indwelling devices.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Incomplete COVID Surveillance and Return-to-Work Tracking
F
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

The facility failed to fully document infection surveillance and RTW decisions during a COVID outbreak. Multiple staff members reported symptoms such as sore throat, headache, congestion, diarrhea, vomiting, fever, and cough, but the employee illness logs were incomplete and left the RTW date blank, with no indication they were tested for COVID or cleared per CDC guidance. At the same time, multiple residents were diagnosed with COVID and others had GI symptoms with unknown testing status. The IP said she worked infection control only a few hours per week and had not thoroughly reviewed the logs for trends, while the DON had not been reviewing the surveillance logs.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Cross Contamination During Dressing Change and Infection Control Program Deficiencies
E
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Cross contamination occurred during a dressing change when an LPN placed a resident’s foot directly on the wheelchair seat without a barrier and did not clean the bedside table after the procedure. The facility also lacked infection surveillance documentation for several months, and its Legionella water management plan was incomplete, with no mapping of high-risk areas, no temperature logs, and no documented preventive measures for unused areas.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Infection Control Failures During Resident Care
E
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Infection Control Failures During Resident Care: Staff did not follow PPE, hand hygiene, and equipment-cleaning practices during care for several residents. An RN failed to clean a glucometer and basket after blood sugar checks, a CNA and a Central Supply staff member entered rooms with enhanced barrier precautions without PPE, and an LVN did not clean the glucometer or insulin vial, and did not properly perform hand hygiene during insulin administration and after emptying a urinal. Residents involved had significant cognitive impairment, diabetes, wounds, and other serious diagnoses.

Inspection fine: $27,378
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Infection Control Lapses in Laundry Services and Policy Review
F
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Infection control failed during laundry services when staff reported using the same personal T-shirt for handling dirty laundry and then hanging clean laundry, while using disposable gowns only for laundry from a resident with an infection. The DON also acknowledged that the Infection Prevention Program policy was overdue for annual review, and the policy showed no indication of an annual review.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Florida

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Florida — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release August 26, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.