F0759 F759: Ensure medication error rates are not 5 percent or greater.
D

Medication Administration Error Exceeds Acceptable Rate

Hillside Manor Rehab & Extended Care CenterJamaica Est, New York Survey Completed on 04-01-2025

Summary

The facility was cited for a medication administration error resulting in a medication error rate of 7.14%, exceeding the acceptable threshold of less than 5%. During the recertification survey, it was observed that an LPN administered the wrong medication to a resident. Specifically, the LPN gave [MEDICATION NAME] Silver Ultra Men's 300 mcg-60 mcg-600 mcg-300 mcg instead of the prescribed [MEDICATION NAME] Silver 0.4 mg-300 mcg 250 mcg. The error occurred because the LPN did not find the correct medication in the medication cart and mistakenly selected a medication intended for another resident. The LPN admitted to signing off on medications before administering them, intending to give all medications at the same time for convenience. This practice was against the facility's policy, which requires medications to be charted immediately after administration. The LPN also acknowledged not recognizing the correct medication due to unfamiliarity with its listing under another name. Interviews with the unit supervisor and the Medical Director confirmed that the medication was available but not correctly identified by the LPN. The facility's policy prohibits borrowing medications from one resident for another, and the error highlighted a lapse in adherence to the five rights of medication administration.

Plan Of Correction

Plan of Correction: Approved April 25, 2025 **NOTE- TERMS IN BRACKETS HAVE BEEN EDITED TO PROTECT CONFIDENTIALITY** **F759** I. Immediate Corrective Action: 1) On 3/26/25 Resident # 320 was assessed by the MD/NP and no adverse effects of receiving late administration of [MEDICATION NAME] and the administration of a different type of [MEDICATION NAME] were noted. 2) On 3/26/25 a medication error report was developed by the DON for this incident and shared with Pharmacy Consultant and Medical Director. 3) On 4/1/25 the DON issued a disciplinary action for LPN# 3 responsible for the medication error. 4) On 4/1/25 a Medication competency was conducted by the RNS for LPN #3. II. Identification of Others: 1) The facility respectfully states that all residents were potentially affected. 2) The DON conducted a meeting with the Medical Director and Pharmacy consultant to review any medication errors in the past 3 months to assess Facility medication error rate. No medication errors were reported. III. Systemic Changes: The DON, Medical Director and Administrator in conjunction with the Pharmacy Consultant reviewed the Facility policies/procedures for medication administration and found same to be compliant. The P/P will be inserviced to all Licensed Medication nurses by the Inservice Coordinator. The Lesson plan will focus on: - Standard for safe medication practices: The Rights of Medication Administration that include: - Right patient - Right drug - Right dose - Right route - Right time - Right reason - Right Monitoring (including vital signs and observation for side effects) - Right documentation - Right patient education - Right evaluation - Right to refuse. - Types of Medication Errors - Medication Documentation and communication. IV. Quality Assurance 1) The DON will develop an audit tool to monitor compliance with ensuring compliance with standards of practice for Medication Administration. 2) The audit will be done by the DON/Designee on 4 randomly selected medication nurses on random shifts weekly x 4 weeks, followed by 4 randomly selected medication nurses monthly x 6 months. 3) All Nurses will continue to have a Medication Competency upon hire and annually completed by the Inservice Coordinator /Designee. 4) Results from the audit will be brought to the Quarterly QA Meeting to monitor compliance and track sustainability. V. Date of Correction and Person Responsible for this F Tag: 05/29/2025 - Director of Nursing

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0759 citations
Insulin Administration Errors and Failure to Prime Insulin Pens
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Surveyors identified that the facility exceeded the acceptable medication error rate when two residents with type 2 DM received insulin doses that were not administered according to orders or manufacturer instructions. In two separate observations, an LPN administered Novolog and another LPN administered insulin glargine and insulin lispro without priming the insulin pens, and the insulin lispro and Novolog were given after the residents had already consumed a significant portion of their breakfast meals, despite orders for administration before meals. Manufacturer information for both insulin products required priming before each injection to ensure accurate dosing, and facility policy required medications, including insulin, to be administered safely, timely, and in accordance with prescriber orders and specified time frames.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Ensure Accurate Medication Dosage Identification During Medication Pass
E
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

The facility failed to maintain medication error rates below 5% when an LPN, during a medication pass for a resident receiving Metamucil for constipation and a cranberry supplement for UTI prevention, was unable to identify the correct dosages for these ordered medications. Despite a policy requiring adherence to the rights of medication administration, including the right dose, the LPN reported that the orders should have been clarified to specify the exact dose, indicating medications were being prepared and administered without clear dosage understanding and contributing to an overall medication error rate above the acceptable threshold.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Maintain Acceptable Medication Error Rate and Proper Medication Timing
E
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Surveyors found that the facility did not maintain a medication error rate below 5%, identifying multiple late and improperly timed medication administrations and a missing medication. A medication aide gave a cholesterol medication and wound-healing supplements significantly later than their scheduled times, and another aide administered acetaminophen well outside the ordered time window and could not obtain a prescribed dose of Ingrezza because it had not arrived from the pharmacy. An LPN administered fast-acting Humalog insulin before a meal when no food was available and was unaware of the required timing of insulin in relation to meals, while the facility’s insulin policy lacked guidance on meal-related timing despite manufacturer instructions specifying administration within 15 minutes before or immediately after eating.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Error Rate Above 5% Due to Incorrect Dosing and Insulin Pen Technique
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Surveyors identified a medication error rate of 7.41%, exceeding the 5% threshold, involving two residents and two LPNs. In one case, a resident with dementia and hypertension received 5 mg of donepezil instead of the 10 mg dose ordered. In another case, a resident with DM2 received insulin lispro via a KwikPen that was not primed, and the LPN held the dose knob for only about 2 seconds instead of the manufacturer-recommended 5 seconds. The DON reported that staff had not been educated on proper insulin pen priming, and facility policy requires verification of the correct medication and dose before administration.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Administration Errors and Unavailable Ordered Medications
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Surveyors identified an 11.1% medication error rate when an LPN did not administer a resident’s ordered nifedipine ER dose because it was not available in the cart or pyxis, and proceeded with the rest of the medications. In a separate instance, an RN administered furosemide despite the order having been discontinued and gave magnesium oxide instead of the ordered SlowMag, explaining that he relied on scanning multi-drug packets rather than individually verifying each medication against the MAR, and knowingly substituted magnesium oxide when SlowMag was unavailable.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Error Rate Exceeded Due to Unavailable Ordered Medications
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

The facility failed to keep its medication error rate below 5% when a resident with dementia, COPD, diabetes, and depression did not receive ordered doses of Singulair and calcium/vitamin D3 because the medications were not available at the time of administration. An RN attempted to pass the morning medications but was unable to administer these two ordered drugs, and later confirmed their unavailability, resulting in two errors out of 33 medication opportunities and an overall error rate of 6.06%.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across New York

Get a heads-up on the newest immediate-jeopardy (J–L) citations in New York — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release August 26, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.