F0880 F880: Provide and implement an infection prevention and control program.
D

Inadequate Infection Control Practices During Resident Care

White County Rehab And NursingCarmi, Illinois Survey Completed on 02-21-2025

Summary

The facility failed to provide proper perineal, urinary catheter, and wound care for a resident, identified as R1, who was admitted with diagnoses including enterocolitis due to clostridium difficile, local infection of the skin and subcutaneous tissue, flaccid hemiplegia, and cerebral infarction. R1 was cognitively intact and dependent on staff for toileting hygiene and transfers. The care plan for R1 included interventions for infection control due to C-Difficile and the presence of an indwelling urinary catheter, emphasizing good hand hygiene and enhanced barrier precautions. On the day of observation, two CNAs, V4 and V5, assisted R1 from a wheelchair to a bed using a mechanical lift. During this process, V5 removed R1's soiled pants and placed the urinary catheter collection bag on the fitted sheet. V5 used a disposable under pad sprayed with peri wash to clean feces from R1's body, employing a wipe and wad method, which left feces on the urinary catheter tubing. V5 changed gloves without performing hand hygiene and continued cleaning R1 with the same method. V5 also handled the peri wash bottle with soiled gloves and did not prevent traction on the urinary catheter tubing, causing it to move in and out of the urethra. Later, an LPN, V8, entered the room to perform wound care, placing supplies on an uncleaned bedside table and a feces-soiled cloth pad. V8 and V4 continued to handle supplies and assist R1 without proper hand hygiene. Additional CNAs, V6 and V7, entered the room, and V7 attempted to put the urinary catheter collection bag through a pant leg without realizing the privacy cover was soiled with feces. Throughout the process, staff failed to follow the facility's infection control policies, including proper hand hygiene, use of clean materials for each area cleansed, and maintaining a clean environment for wound care.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0880 citations
Failure to Follow Enhanced Barrier Precautions During Wound Care
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

A resident with a chronic heel wound with drainage, classified as high risk under the facility’s Enhanced Barrier Precautions (EBP) policy, received wound care from a Wound Nurse and a NA who wore masks and gloves but did not don gowns during multiple high-contact wound care activities on both lower extremities. The facility’s EBP policy requires both gloves and gowns for high-contact care, including wound care, for residents with chronic wounds. At the time of care, there was no EBP sign on the door and no PPE caddie or supplies outside the room. In subsequent interviews, the Wound Nurse and NA reported they did not wear gowns because there was no sign on the door and the nurse was not wearing one, while the IP and DON stated they would have expected gown use and confirmed that wound care is considered a high-contact activity under the policy.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Implement and Follow Enhanced Barrier Precautions During Wound Care
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Staff failed to consistently implement and follow Enhanced Barrier Precautions (EBP) during wound care for two residents. For a resident with an indwelling urinary catheter and an EBP order, an RN and a CNA removed their gowns after catheter care and performed a heel and toe dressing change wearing only gloves, despite a door sign requiring gown and gloves for wound care and other high-contact care. For another resident with multiple open leg wounds and active wound care orders, an RN and a nurse aide performed dressing changes with gloves only, without gowns, and there was no EBP signage or order in place. Interviews with nursing staff, the IP, and the DON revealed inconsistent understanding and application of the facility’s EBP policy, which requires gown and gloves for high-contact care activities, including wound care and device care, for residents with chronic wounds or indwelling devices.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Incomplete COVID Surveillance and Return-to-Work Tracking
F
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

The facility failed to fully document infection surveillance and RTW decisions during a COVID outbreak. Multiple staff members reported symptoms such as sore throat, headache, congestion, diarrhea, vomiting, fever, and cough, but the employee illness logs were incomplete and left the RTW date blank, with no indication they were tested for COVID or cleared per CDC guidance. At the same time, multiple residents were diagnosed with COVID and others had GI symptoms with unknown testing status. The IP said she worked infection control only a few hours per week and had not thoroughly reviewed the logs for trends, while the DON had not been reviewing the surveillance logs.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Cross Contamination During Dressing Change and Infection Control Program Deficiencies
E
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Cross contamination occurred during a dressing change when an LPN placed a resident’s foot directly on the wheelchair seat without a barrier and did not clean the bedside table after the procedure. The facility also lacked infection surveillance documentation for several months, and its Legionella water management plan was incomplete, with no mapping of high-risk areas, no temperature logs, and no documented preventive measures for unused areas.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Infection Control Failures During Resident Care
E
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Infection Control Failures During Resident Care: Staff did not follow PPE, hand hygiene, and equipment-cleaning practices during care for several residents. An RN failed to clean a glucometer and basket after blood sugar checks, a CNA and a Central Supply staff member entered rooms with enhanced barrier precautions without PPE, and an LVN did not clean the glucometer or insulin vial, and did not properly perform hand hygiene during insulin administration and after emptying a urinal. Residents involved had significant cognitive impairment, diabetes, wounds, and other serious diagnoses.

Inspection fine: $27,378
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Infection Control Lapses in Laundry Services and Policy Review
F
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Infection control failed during laundry services when staff reported using the same personal T-shirt for handling dirty laundry and then hanging clean laundry, while using disposable gowns only for laundry from a resident with an infection. The DON also acknowledged that the Infection Prevention Program policy was overdue for annual review, and the policy showed no indication of an annual review.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Illinois

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Illinois — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release August 26, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.