F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
J

Failure to Adhere to Care Plans and Use Appropriate Equipment

Regents Park Of Winter ParkWinter Park, Florida Survey Completed on 12-13-2024

Summary

The facility failed to prevent an avoidable fall from a full body mechanical lift for a vulnerable, physically impaired resident. The resident's care plan required assistance from two staff members for transfers with a full body mechanical lift, but a CNA attempted the task single-handedly. During the transfer, one of the sling's loops detached from the lift, causing the resident to fall to the floor, resulting in blunt head trauma and a fracture of the sacrum. The resident developed a fear of using the mechanical lift, which affected her quality of life by limiting her participation in usual activities. Another incident involved the facility's failure to ensure the use of the appropriate type of mechanical lift for a physically impaired resident. The resident's assigned CNA neglected to review the care plan or kardex and attempted to transfer him with a sit-to-stand lift instead of the required full body lift. The resident exhibited noticeable weakness and poor balance, placing him at high risk for an adverse outcome as he was unable to stand. This oversight demonstrated a lack of adherence to the resident's care plan, which required two staff members to perform transfers with a full body mechanical lift. These failures in adhering to care plans and using the appropriate equipment placed residents at risk for serious injury. The incidents highlighted the facility's inability to follow its policies and procedures, contributing to a fall and fracture for one resident and potential harm for another. The deficiencies were identified during a survey, and the facility was notified of the Immediate Jeopardy status due to these failures.

Removal Plan

  • The evening shift Nursing Supervisor immediately placed the mechanical lift and sling out of service.
  • The CNA who failed to follow correct procedure for use of mechanical lift using two staff members was immediately suspended.
  • The Weekend Nursing Supervisor began education and skills validation with 13 of 24 CNAs duty on the day, evening and night shifts.
  • An Ad Hoc Quality Assurance and Performance Improvement (QAPI) meeting was held with the facility Administrator, Director of Nursing, and Medical Director to review the initial incident.
  • The Therapy Director completed resident transfer status evaluations on current residents. Any updates were placed in the kardex and care plans.
  • The MDS coordinator completed care plan/kardex reviews to ensure appropriate transfer status was on care plan/kardex for current residents.
  • The MDS Coordinators completed a quality review of current residents for MDS accuracy related to transfer status. Corrections were made as identified. Quality reviews were then completed on current resident care plans and kardexes to ensure accurate transfer status were listed. Corrections were made when identified.
  • The Maintenance Director inspected all mechanical lifts and slings for any malfunctions and no concerns were identified.
  • Current nursing staff were educated on mechanical lift usage and competencies were performed by the Director of Nursing, Staff Development Coordinator, and Nurse Managers. Occupational and Physical Therapy staff were educated on mechanical lift usage. Of 91 total nursing staff, 80 total current nursing staff received education, and 11 total nursing staff members were to receive education prior to next shift worked. Of 27 total Occupational and Physical Therapy staff, 26 total current therapy staff received education, and 1 total therapy staff member was to receive education prior to next shift worked. There are no contracted licensed nurses or CNAs currently on staff. Any contracted nurses or CNAs who are placed at the facility on assignment will receive the above education prior to starting their shift through an agency orientation packet.
  • Current facility staff were educated on abuse, neglect and exploitation by the Administrator, Director of Nursing, Staff Development Coordinator, and Nurse Managers. Of 171 total staff, 171 current staff received education. There are no staff members who require education prior to next shift worked, and no contracted licensed nurses or CNAs on staff. Any contracted nurses or CNAs who are placed at the facility on assignment in the future will receive the above education prior to starting their shift through an agency orientation packet.
  • An Ad Hoc QAPI meeting was completed with the Medical Director, Administrator, and DON. The topics of the incident, abuse and neglect, use of mechanical lifts, mechanical lift competencies, updating care plans/kardex, and following care plans/kardex were discussed.
  • An Ad Hoc QAPI meeting was held with the Medical Director, Administrator, DON, Staff Development Coordinator, IDT members, and Nurse Managers to review the 4-Point Plan and Investigation.
  • An Ad Hoc QAPI meeting was held with the Medical Director, Administrator, DON and IDT members to include the Director of Rehabilitation, to review the 4-Point Plan, Root Cause Analysis, and progression of investigation.
  • An Ad Hoc QAPI meeting was held with the Medical Director, Administrator, DON and IDT team to include the Director of Rehabilitation, to review the 4-Point Plan progress, quality reviews, and conclusion of investigation.
  • The Unit Manager corrected the assigned CNA on the proper way to transfer resident #2 and showed her the transfer status on the kardex. The CNA was suspended pending investigation and re-educated on checking the kardex prior to transfers.
  • Nursing staff re-education on how to view kardex for transfer status was initiated with return demonstration required. Of 92 nursing staff members, 43 total nursing staff were re-educated. Other staff will be educated prior to the beginning of their next shift by the Director of Nursing or designee, and 49 nursing staff members will be educated prior to the beginning of their next shift.
  • Nursing staff competencies were initiated by the Director of Nursing or designees. Of 92 nursing staff members, 43 total nursing staff were re-educated. Other staff will be educated prior to the beginning of their next shift, by the Director of Nursing or designee, and 49 nursing staff members will be educated prior to the beginning of their next shift.
  • An Ad Hoc QAPI meeting was held with the Medical Director, Administrator, DON, and IDT team to include Director of Rehabilitation, to discuss areas of concern that were identified during the complaint survey and additional steps the facility is taking to re-educate staff.
  • An Ad Hoc QAPI meeting was held with the Medical Director, Administrator, DON, and IDT team to include Director of Rehabilitation, to go over Kardex education, discuss quality monitoring tools, root cause of concerns, and clarify areas of concerns.

Penalty

Inspection fine: $235,730
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0689 citations
Failure to Control Razors, Sharps, and Chemical Wipes Creating Accident Hazards
D
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

Surveyors found that the facility failed to keep the environment free of accident hazards when a resident’s room contained an unattended shaving razor on the sink and additional razors in a nightstand, despite leadership stating razors were not permitted in resident rooms. An LPN disposed of unused lancets in regular trash instead of a sharps container, contrary to acknowledged policy. On two occasions, an unattended housekeeping cart on an upper floor had germicidal wipes left on top and easily accessible, even though housekeeping leadership and staff stated that chemicals and disinfectant wipes were to be kept locked in the cart for safety.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Assess Safe Use of Lift Reclining Chair
D
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

A resident with severe cognitive impairment, dementia, a history of falls, and dependence on staff for transfers was observed using a lift reclining chair even though the care plan and physical device review did not identify that device. Therapy staff lowered the chair and placed the remote next to the call light on the resident’s lap, and staff stated they were not aware of any formal assessment for safe use of the lift chair. The DON stated the resident should have had an assessment to determine whether she was safe to have the lift chair.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Follow Transfer and Sling Size Interventions
D
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

A resident with severe cognitive impairment, dementia with behavioral disturbances, and fall risk interventions in place was transferred by staff using methods that did not match the care plan and Kardex. Staff used a transfer belt for some transfers, then later used a Hoyer lift from mattresses on the floor to a wheelchair, but used a green sling even though the resident required a yellow sling based on weight. The RN, LPN, DON, and PT verified the resident’s transfer status and sling instructions were not updated to reflect current needs.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Complete Required Quarterly Smoking Safety Assessments
D
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

A resident with nicotine dependence was care planned as a smoker who could go out to smoke at designated times or with family, with an intervention that a smoking evaluation be completed quarterly. The last documented smoking safety evaluation showed the resident could safely smoke with supervision, but no additional evaluations were completed for several months, contrary to facility policy requiring smoking assessments at admission, readmission, with significant change, and quarterly by a licensed nurse, even though the resident continued to smoke under staff and family supervision in the courtyard.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Supervise Smokers and Secure Smoking Materials
J
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

Failure to supervise smokers and secure smoking materials. Surveyors found that 27 smokers were not adequately monitored and that residents were able to keep cigarettes and lighters in their possession despite care plan directions to return them after smoking. One resident with severe cognitive impairment, dementia, schizophrenia, and continuous oxygen use was observed with cigarettes and a lighter while on oxygen, and staff confirmed she was an unsafe smoker requiring direct supervision.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Code Alert System Failed to Prevent Resident Elopement
J
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

Code Alert System Failed to Prevent Resident Elopement: The facility failed to keep the code alert system functioning as intended and did not follow the manufacturer’s weekly testing and inspection guidance. Two residents with significant cognitive impairment were able to get through the main doors, and one resident exited the building before staff followed outside. The report also states that multiple residents with code alert devices did not have adequate elopement or wandering assessments and care plan interventions, and several attempts to leave were not documented in the record.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Florida

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Florida — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release August 26, 2026) and official state health department websites — never guesswork.