F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
E

Deficiencies in Enteral Feeding Management

Ridgmar Medical LodgeFort Worth, Texas Survey Completed on 11-14-2024

Summary

The facility failed to ensure proper management of enteral feeding for two residents, leading to deficiencies in their nutritional care. Resident #44, a male with a history of stroke, dementia, and dysphagia, was not provided with the prescribed amount of enteral nutrition. RN E, who had recently started working at the facility, misread the physician's orders and administered only one carton of formula instead of the required two during bolus feedings. This error persisted for three days, potentially compromising the resident's nutritional intake. The Director of Nursing (DON) and the dietitian acknowledged the risk of inadequate nutrition due to this oversight. Resident #84, a female with severe cognitive impairment and dysphagia, was also affected by improper enteral feeding management. Her tube feeding machine was observed to be off during scheduled feeding times on multiple occasions. LVN O and LVN SS, responsible for the resident's care, failed to ensure the machine was turned on at the correct times, resulting in the resident not receiving the full 20 hours of prescribed nutrition. This lapse in care was attributed to miscommunication and assumptions between the nursing staff during shift changes. The facility's policies on enteral nutrition and tube feeding were not adequately followed, as evidenced by the discrepancies in the administration of feeding orders for both residents. The DON admitted to a lack of training on g-tube feeding and acknowledged the need for staff to adhere to physician orders to prevent nutritional deficiencies. The facility's failure to provide the necessary nutritional support as per the residents' care plans and physician orders posed a risk of weight loss and inadequate nutrition for the affected residents.

Penalty

Inspection fine: $16,67513 days payment denial
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0693 citations
Incorrect G-tube Flush Volume During Enteral Feeding
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

Incorrect G-tube Flush Volume During Enteral Feeding: A resident with severe cognitive impairment, aphasia, stroke, hemiplegia, and a feeding tube was observed receiving enteral feeding when an RN flushed the G-tube with 30 ml of water before and after the feeding instead of the ordered 60 ml. The RN stated he read the order wrong, and the DON and ADON confirmed the correct flush amount should have been followed.

Inspection fine: $9,821
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Provide Ordered Hydration and Correct Tube Flushes for Enteral Feeding
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with moderate cognitive impairment, multiple comorbidities, and NPO status received nutrition and hydration via a gastrojejunal tube with orders for continuous tube feeding, 30 mL water flushes before and after medications via the gastric port, 120 mL free water flushes six times daily, and 30 mL jejunal port flushes every four hours. During observed care, an LPN administered medications and 30 mL water flushes through the gastric port but did not provide the ordered 120 mL free water flush or the 30 mL jejunal port flush, and no additional flushes were given over several hours. Later, another LPN initially attempted to give medications through the jejunal port before being redirected, and documentation on the MAR/TAR showed inconsistent flush volumes of 30–60 mL instead of the ordered 120 mL free water flushes, reflecting failure to consistently implement the prescribed hydration and port-specific flushing regimen.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Improper Head-of-Bed Positioning During Tube Feeding
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident receiving enteral tube feeding was observed lying with the HOB elevated only 15 degrees while Glucerna was infusing at 60 ml/hr. An LVN started the feeding and was unsure of the correct HOB position, and an RN stated the HOB was not elevated properly to prevent aspiration. Records showed an order to keep the HOB elevated 30-45 degrees or as tolerated and a care plan noting tube feeding related to dysphagia.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
GT Site Care and Feeding Position Not Provided as Ordered
E
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

GT site care and feeding precautions were not followed for two residents with GTs. One resident with dementia and severe cognitive impairment had a GT dressing left unchanged despite orders for daily cleansing and dressing changes, and drainage was observed at the site. Another resident was observed lying flat in a supine position while receiving continuous GT feeding, even though the CP and OSR required HOB elevation during tube feeding; RN and DON confirmed the ordered positioning was not being followed.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Expired Tube Feeding Formula Left Connected to Resident
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

Expired Tube Feeding Formula Left Connected to a Resident: A resident with anoxic brain damage, dysphagia, and a gastrostomy tube was observed with an enteral feeding pump off but still connected and a tube feeding bag that staff said had exceeded the 24-hour limit after opening. Staff confirmed the formula was no longer safe after 24 hours, and the facility policy required accurate labeling and dating of each feeding bag or formula container.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Incorrect Enteral Feeding Formula Administered Contrary to Physician Order
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with an order for Glucerna 1.2 at a specified rate and duration was instead observed receiving Isosource at 60 ml/hour. Record review confirmed the physician’s order for Glucerna 1.2, while observation and interview with an LPN verified that Isosource, a different enteral formula, was being administered. The DON later stated that the LPN should have verified the physician’s order before administering the tube feeding.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Texas

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Texas — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release August 26, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.