F0700 F700: Try different approaches before using a bed rail. If a bed rail is needed, the facility must (1) assess a resident for safety risk; (2) review these risks and benefits with the resident/representative; (3) get informed consent; and (4) Correctly install and maintain the bed rail.
E

Improper Use of Bed Rails for Non-Ambulatory Residents

Alameda Healthcare & Wellness CenterAlameda, California Survey Completed on 08-10-2024

Summary

The facility failed to ensure the appropriate use of bed rails for three residents, increasing the risk of entrapment or injury. The facility's policy on bed rails, revised in November 2022, states that bed rails should only be used to treat a resident's medical symptoms and not for staff convenience or as a form of discipline. Despite this, observations and interviews revealed that bed rails were improperly used for residents who could not benefit from them due to their medical conditions. Resident 30, who was non-ambulatory and had bilateral upper extremity contractures, was observed with bilateral half rails on her bed. Her care plan included the use of bedrails for bed mobility, but her bed rail assessment indicated that side rails were not necessary. The Director of Nursing (DON) confirmed that Resident 30 was unable to use the bed rails and that they should not have been present. Similarly, Resident 53, who was in a persistent vegetative state and had contractures, was observed with bilateral enabler bars. Although his care plan and order history included the use of these bars, his assessment showed that he could not use them independently. The DON confirmed the inappropriateness of the enabler bars. Resident 99, also non-ambulatory with contractures, was found with quarter side rails, despite her assessment indicating no need for them. The DON acknowledged that these side rails were unnecessary and should be removed.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0700 citations
Bed rails used without required orders, consent, assessments, and care plans
E
F0700 F700: Try different approaches before using a bed rail. If a bed rail is needed, the facility must (1) assess a resident for safety risk; (2) review these risks and benefits with the resident/representative; (3) get informed consent; and (4) Correctly install and maintain the bed rail.
Short Summary

Bed rails were used for three residents without the required documentation and authorization. One resident with hemiplegia and fluctuating decision-making capacity had bilateral half side rails in use, but RN and DON stated there was no current physician order or care plan for side rail use. Two other residents, including one with Alzheimer's disease and seizures and another with hemiplegia and intact cognition, had orders and assessments for 1/4 rails, but were observed or documented with 1/2 rails instead; the DSD and DON stated the specific 1/2 rail use lacked the proper order, informed consent, assessment, and care plan.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Obtain Consent and Order for Four Side Rails
D
F0700 F700: Try different approaches before using a bed rail. If a bed rail is needed, the facility must (1) assess a resident for safety risk; (2) review these risks and benefits with the resident/representative; (3) get informed consent; and (4) Correctly install and maintain the bed rail.
Short Summary

A resident with intracranial hemorrhage, respiratory failure, and hypertensive emergency was observed with all four bed rails raised, even though the physician's order and informed consent only addressed bilateral upper half side rails. Staff interviews confirmed the resident was being positioned with four side rails without a specific order or consent for that setup, and the facility policy required informed consent before bed rail use.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Reassess Bedrail Use and Risk
D
F0700 F700: Try different approaches before using a bed rail. If a bed rail is needed, the facility must (1) assess a resident for safety risk; (2) review these risks and benefits with the resident/representative; (3) get informed consent; and (4) Correctly install and maintain the bed rail.
Short Summary

The facility failed to complete ongoing accurate assessments for bedrail use for two residents. One resident had weakness, a right BKA, and bilateral enabler bars, while another had CVA with left-sided paralysis and a left enabler bar. Both residents’ last Enabler/Assist Rail/Device Evaluation - V2 assessments were completed about a year earlier, and the ADON confirmed assessments should be done quarterly.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Bedrails Installed Without Assessment or Informed Consent
D
F0700 F700: Try different approaches before using a bed rail. If a bed rail is needed, the facility must (1) assess a resident for safety risk; (2) review these risks and benefits with the resident/representative; (3) get informed consent; and (4) Correctly install and maintain the bed rail.
Short Summary

A resident with intact cognition and multiple serious diagnoses had half bedrails placed on both sides of his bed without a documented side rail assessment, informed consent, or evidence that alternatives were tried first. Staff interviews showed the Maintenance Supervisor was told to install the rails without being shown a signed consent, while RN and ADON staff were unaware the rails were in place or that the required documentation was missing. The resident stated he did not request the bedrails and was never spoken to about them.

Inspection fine: $51,756
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Inconsistent Bed Rail Assessment and Use After Resident Falls
D
F0700 F700: Try different approaches before using a bed rail. If a bed rail is needed, the facility must (1) assess a resident for safety risk; (2) review these risks and benefits with the resident/representative; (3) get informed consent; and (4) Correctly install and maintain the bed rail.
Short Summary

A resident with severe cognitive impairment and a history of recent falls was repeatedly observed asleep in bed with bilateral upper grab rails elevated. The care plan, updated after the falls, included side rails as grab bars for fall prevention and assistance with repositioning, but the bed rail assessment documented that side rails or assist bars were not indicated, and no bed rail entrapment risk assessment was found. Staff interviews confirmed that the resident used the grab rails for turning and repositioning and that the care plan called for grab bars despite the assessment indicating otherwise, resulting in a deficiency for failing to ensure safe and properly assessed side rail use.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Document Alternatives, Risk-Benefit Discussion, and Informed Consent for Side Rail Use
D
F0700 F700: Try different approaches before using a bed rail. If a bed rail is needed, the facility must (1) assess a resident for safety risk; (2) review these risks and benefits with the resident/representative; (3) get informed consent; and (4) Correctly install and maintain the bed rail.
Short Summary

The facility failed to document alternative measures, risk-benefit discussion, and informed consent before side rail use for two residents. One resident with ESRD and severe cognitive impairment and another resident with dementia and intellectual disabilities were observed with side rails raised in bed, but records showed no current order for side rails and no documented evidence that alternatives were explored or that risks and benefits were reviewed with the resident or RP.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across California

Get a heads-up on the newest immediate-jeopardy (J–L) citations in California — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release August 26, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.