F0880 F880: Provide and implement an infection prevention and control program.
K

Improper Disinfection of Shared Glucometers

Crescent Health And Rehabilitation CenterSarasota, Florida Survey Completed on 09-12-2024

Summary

The facility failed to maintain an ongoing infection prevention and control program by not ensuring that shared glucometers were properly disinfected between each resident use. This deficiency was observed over two days, where multiple licensed nurses on different shifts and units used shared glucometers without disinfecting them between uses. The nurses did not follow the manufacturer's specifications for disinfection, which placed residents at risk of exposure to blood-borne diseases. During observations, several nurses were seen using glucometers on multiple residents without proper disinfection. For instance, a registered nurse used a glucometer on five residents without disinfecting it between uses and did not follow standard precautions such as wearing gloves. Another nurse was observed cleaning the glucometer with an alcohol pad for only 15 seconds, which was insufficient according to the manufacturer's instructions. Additionally, a licensed practical nurse admitted to not disinfecting the glucometer between resident uses, stating it had slipped her mind. The facility did not have a policy for disinfecting glucometers, and the Director of Nursing was unable to provide one when requested. The lack of a clear policy and proper training contributed to the improper disinfection practices observed. The Medical Director acknowledged the risk of cross-contamination and the need for proper disinfection procedures, highlighting the potential for transmission of blood-borne pathogens such as HIV and HBV.

Removal Plan

  • Residents #46, #34, and #82 were assessed by a licensed nurse to ensure no adverse effects were noted from the alleged deficient practice.
  • RN Staff A, LPN Staff B, and RN Staff D were re-educated by the Director of Nursing/Designee on proper disinfecting of the glucometer machine and provided a return demonstration on proper disinfecting of glucometer machine.
  • An Ad Hoc Quality Assurance Meeting was held with the facility Medical Director and other team members to approve recommendations and develop a Performance Improvement Plan based on Root Cause Analysis.
  • All current licensed nurses received prior education and completed return demonstration competencies on disinfection of glucometers during orientation or skills fair training.
  • Current residents who received blood glucose monitoring were assessed by a licensed nurse to ensure no adverse effects were noted for the alleged deficient practice.
  • Current licensed nurses were re-educated in person or via phone by the Assistant Director of Nursing/Designee on the process for glucometer disinfection.
  • The facility initiated training with current licensed nurses on disinfecting glucometers and completed competencies with return demonstration.
  • The facility implemented a new process where each resident requiring blood glucose monitoring will be provided with their own individual glucometer machines stored in plastic containers with lids and their names.
  • The facility reviewed the new process changes of individualized glucometers and the implementation of baskets on the nurses med carts to hold the sanitizer, timer, instructions for disinfections and contact time marked on the disinfectant wipe.
  • Each cart had a timer to ensure the wet contact time per manufacturer's specification for the disinfecting wipes.
  • The Medical Director was contacted to review the recommendations for monitoring of the current residents potentially affected by the alleged deficient practice; new orders received for monitoring CBC with Diff once in the morning and then again in 7 days; also monitor vital signs every day for duration of 7 days.
  • The Infection Preventionist was re-educated on proper disinfection of glucometer machine by the Director of Nursing and provided return demonstration on proper disinfection of glucometer machines.
  • Newly hired nurses will be educated on proper disinfection of glucometers by the Assistant Director of Nursing/Designee and provide return demonstration as part of orientation.
  • In the event that the facility would need to utilize licensed agency staff, those licensed agency nurses would be educated on proper disinfection of glucometers and provide return demonstration.
  • DON/Designee will conduct audits on five nurses to ensure proper disinfection of blood glucose machines is maintained. Findings of the audits will be reviewed in the Quality Assurance Meetings.

Penalty

Inspection fine: $40,820
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0880 citations
Failure to Follow Enhanced Barrier Precautions During Wound Care
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

A resident with a chronic heel wound with drainage, classified as high risk under the facility’s Enhanced Barrier Precautions (EBP) policy, received wound care from a Wound Nurse and a NA who wore masks and gloves but did not don gowns during multiple high-contact wound care activities on both lower extremities. The facility’s EBP policy requires both gloves and gowns for high-contact care, including wound care, for residents with chronic wounds. At the time of care, there was no EBP sign on the door and no PPE caddie or supplies outside the room. In subsequent interviews, the Wound Nurse and NA reported they did not wear gowns because there was no sign on the door and the nurse was not wearing one, while the IP and DON stated they would have expected gown use and confirmed that wound care is considered a high-contact activity under the policy.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Implement and Follow Enhanced Barrier Precautions During Wound Care
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Staff failed to consistently implement and follow Enhanced Barrier Precautions (EBP) during wound care for two residents. For a resident with an indwelling urinary catheter and an EBP order, an RN and a CNA removed their gowns after catheter care and performed a heel and toe dressing change wearing only gloves, despite a door sign requiring gown and gloves for wound care and other high-contact care. For another resident with multiple open leg wounds and active wound care orders, an RN and a nurse aide performed dressing changes with gloves only, without gowns, and there was no EBP signage or order in place. Interviews with nursing staff, the IP, and the DON revealed inconsistent understanding and application of the facility’s EBP policy, which requires gown and gloves for high-contact care activities, including wound care and device care, for residents with chronic wounds or indwelling devices.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Incomplete COVID Surveillance and Return-to-Work Tracking
F
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

The facility failed to fully document infection surveillance and RTW decisions during a COVID outbreak. Multiple staff members reported symptoms such as sore throat, headache, congestion, diarrhea, vomiting, fever, and cough, but the employee illness logs were incomplete and left the RTW date blank, with no indication they were tested for COVID or cleared per CDC guidance. At the same time, multiple residents were diagnosed with COVID and others had GI symptoms with unknown testing status. The IP said she worked infection control only a few hours per week and had not thoroughly reviewed the logs for trends, while the DON had not been reviewing the surveillance logs.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Cross Contamination During Dressing Change and Infection Control Program Deficiencies
E
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Cross contamination occurred during a dressing change when an LPN placed a resident’s foot directly on the wheelchair seat without a barrier and did not clean the bedside table after the procedure. The facility also lacked infection surveillance documentation for several months, and its Legionella water management plan was incomplete, with no mapping of high-risk areas, no temperature logs, and no documented preventive measures for unused areas.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Infection Control Failures During Resident Care
E
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Infection Control Failures During Resident Care: Staff did not follow PPE, hand hygiene, and equipment-cleaning practices during care for several residents. An RN failed to clean a glucometer and basket after blood sugar checks, a CNA and a Central Supply staff member entered rooms with enhanced barrier precautions without PPE, and an LVN did not clean the glucometer or insulin vial, and did not properly perform hand hygiene during insulin administration and after emptying a urinal. Residents involved had significant cognitive impairment, diabetes, wounds, and other serious diagnoses.

Inspection fine: $27,378
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Infection Control Lapses in Laundry Services and Policy Review
F
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Infection control failed during laundry services when staff reported using the same personal T-shirt for handling dirty laundry and then hanging clean laundry, while using disposable gowns only for laundry from a resident with an infection. The DON also acknowledged that the Infection Prevention Program policy was overdue for annual review, and the policy showed no indication of an annual review.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Florida

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Florida — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release August 26, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.