F0641 F641: Ensure each resident receives an accurate assessment.
E

Inaccurate Resident Assessments in LTC Facility

William Penn Nursing And RehabLewistown, Pennsylvania Survey Completed on 06-25-2024

Summary

The facility failed to ensure that resident assessments accurately reflected the residents' status, affecting 10 out of 24 residents reviewed. For several residents, the Minimum Data Set (MDS) assessments inaccurately documented the use of physical restraints, specifically bed rails, which were not used as restraints according to the CMS RAI Manual. Residents 60, 41, 97, 109, 32, 55, 63, and 85 were all incorrectly assessed as having bed rails used as restraints, despite evidence showing that these rails were used for bed mobility and not as restraints. Interviews with residents and their family members confirmed that no restraints were used, and the facility's own assessments supported this finding. Additionally, the facility inaccurately documented the use of anticoagulant medications for Residents 19 and 9. The MDS for Resident 19 noted the use of an anticoagulant, but clinical records showed no evidence of such medication being administered during the assessment period. Similarly, Resident 9's MDS indicated anticoagulant use, but a review of medication administration records for March and April 2024 revealed no anticoagulant was given. Interviews with the Nursing Home Administrator and Director of Nursing confirmed these errors in MDS coding. The errors in the MDS assessments were confirmed through interviews with the Director of Nursing, the Nursing Home Administrator, and the Registered Nurse Assessment Coordinator. These inaccuracies in the MDS coding were acknowledged as errors, with the staff confirming that the residents did not have restraints or receive anticoagulants as documented. The facility's failure to accurately assess and document the residents' status led to these deficiencies being identified during the survey.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0641 citations
Inaccurate MDS Assessment Failed to Document Antidepressant Medication
D
F0641 F641: Ensure each resident receives an accurate assessment.
Short Summary

An MDS assessment failed to accurately reflect a resident's status when an antidepressant prescribed for insomnia was not documented on the admission MDS. The resident had Alzheimer's disease and major depressive disorder, and the MDS coordinator later confirmed the assessment was incorrect.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Complete Required Discharge MDS Assessment
D
F0641 F641: Ensure each resident receives an accurate assessment.
Short Summary

A resident was discharged to an acute care hospital, but review of MDS listings showed that no discharge MDS assessment was completed for that resident. The MDS Coordinator acknowledged that a discharge assessment is required whenever a resident leaves the facility and could not explain why it was missed. The Executive Director reported there was no specific facility policy for MDS assessments and that staff relied on the RAI manual for guidance.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Inaccurate MDS Coding for Diabetes Medication
D
F0641 F641: Ensure each resident receives an accurate assessment.
Short Summary

A resident with diabetes had quarterly MDS assessments that incorrectly coded insulin use despite current orders showing weekly semaglutide injections and no insulin orders. The resident stated she did not receive insulin, and an RN confirmed the MDS was coded incorrectly and needed modification. The DON stated the MDS should accurately reflect each resident’s status.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
MDS Incorrectly Omitted BiPAP Use
D
F0641 F641: Ensure each resident receives an accurate assessment.
Short Summary

A resident’s quarterly MDS failed to code use of a non-invasive ventilatory device, even though a BiPAP machine was observed at bedside and the resident stated staff assisted with it at night. The chart also included orders for CPAP/BiPAP use for OSA, and the MDS coordinator confirmed the assessment was coded incorrectly.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Inaccurate MDS Coding for Code Alert Devices
E
F0641 F641: Ensure each resident receives an accurate assessment.
Short Summary

A facility failed to accurately code MDS assessments for code alert device use for multiple residents identified as at risk for elopement and wandering. Although a wander guard log showed several residents had code alert devices, the MDS often stated the devices were not in use and did not reflect wandering behavior. Several care plans also lacked elopement or wandering interventions, and staff interviews confirmed the MDS should reflect code alert placement because it drives the care plan.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Inaccurate MDS Coding for PASARR Status and Antidepressant Use
D
F0641 F641: Ensure each resident receives an accurate assessment.
Short Summary

Inaccurate MDS coding affected two residents. One resident’s PASARR Level II status was coded inconsistently with the record, and another resident’s MDS failed to code an antidepressant on Item N0415 even though the resident was receiving Trazodone for insomnia and had diagnoses including schizoaffective disorder, major depressive disorder, and anxiety.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Know what gets cited — and walk into your next survey with full visibility

We process and analyze inspection reports and Plans of Correction using AI to surface insights and trends — so you can improve care quality and stay ahead of compliance risk before your next survey.

Get ready for your next survey

See what surveyors are citing in your state and spot your risk areas before they do.

Monthly Citation Reports

Have you been cited for this tag?

Save hours drafting a compliant Plan of Correction — AI built on real approved POCs.

Plan of Correction Writer

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release June 24, 2026) and official state health department websites — never guesswork.

Trusted by long-term care providers and associations.

Allegria Senior Living logo
FHCA logo
WeCare Centers logo
Care Rehab logo
An unhandled error has occurred. Reload 🗙